EverFocus EKB500 User Manual page 13

Universal for both dvr remote control and telemetry control of speed domes and telemetry receivers
Hide thumbs Also See for EKB500:
Table of Contents

Advertisement

System settings required for start-up:
DVR:
MENU > RS232/RS485:
RS485
BAUDRATE
STOPBIT
PARITY
DATABIT
RS232/RS485 ID
EKB-500: (for details, please refer to "8. Menu settings")
DVR setting:
MENU ("SHIFT" + "MENU" key) > DEVICE SETTING > DVR SETTING:
DVR NAME:
RS485 CONNECTED TO PORT: _ :
RS485 Address:
DVR xxxx changed
[ENT] to save
MENU > COM PORT SETTING:
Port:_ (1 or 2)
Input the Port
BAUD: 9600<
Protocol: EFV1
Port: 1 Changed
[ENT] to save
For details and further settings (e.g. matrix monitor set-up), please refer to menu description.
9600 BPS
>
1
NONE
8
1
>
Selectable DVR number (independent of RS-485 address)
RS-485 port to which the DVR is connected (1 or 2)
DVR RS-485 address
(complies with DVR menu "RS232/RS485 ID")
Must be in accordance with DVR setting
Press ENTER key to confirm the settings
Enter the RS-485 port to which the DVR is connected
(1 or 2)
Baud rate setting (according to DVR)
Protocol type, setting irrelevant for DVR control> ENTER
Press ENTER key to confirm the settings
Baud rate must be the same as baud rate of
the respective EKB 500 port (default setting
for both keyboard and DVR is 9600)
RS-485 address must correspond to
DVR setting in EKB 500 menu