Gb Gb; Alarm Codes - Zanotti DFZ Use And Maintenance Instructions

Table of Contents

Advertisement

Alarm code
Description
A01
Water temperature alarm
A02
Oil pressure alarm
A03
Thermal relay alarm
A04
Pressure switch alarm
A05
Low battery level alarm
A06
Damaged room sensor alarm
A07
Damaged defrost sensor alarm
A08
Starting failure/damaged alternator
A09
High/low temperature alarm
A10
Radiator water level alarm
A11
Oil level alarm
A12
Air filter alarm
A13
Oil filter alarm
A14
Power card not present
A15
Damaged condensing sensor alarm
A16
Damaged water sensor alarm
A17
Door switch open alarm
A01 Water temperature alarm
This occurs when the radiator's water temperature exceeds the permitted value.
It turns off the diesel engine until the temperature returns to normal values.
A02 Oil pressure alarm
This alarm occurs if the engine's oil pressure drops; it permanently turns off the
diesel engine. To start the machine again, the alarm must be reset using the pro-
cedure described in the paragraph above and by pressing the
A03 Thermal relay alarm
This alarm occurs if abnormal electric motor current input values occur and it
turns off the machine. To reset the alarm, the machine must be de-energized, the
electrical switchboard must be opened, and the thermal relay must be reset by
pressing the blue button. Then close the switchboard and energize the machine
again. Go to the driver's cabin control and press the
Type
Automatic reset
Manual reset
Manual reset
Automatic reset
Automatic reset
Manual reset
Warning only
Manual reset
Warning only
Warning only
Warning only
Warning only
Warning only
Automatic reset
Warning only
Warning only
Automatic reset
ON/OFF key.
ON/OFF key.