SB - GM - ZM - AS - ZS - GS
SPO - DBO - DBS
RCV - RDV
S
CHEMA ELETTRICO
W
IRING DIAGRAM
S
CHEMA ELECTRIQUE
S
CHALTPLAN
E
SQUEMA ELECTRICO
AS
(Rotary)
AS
(Container)
CUH - CUE - CUD - CUB - CUR - CUI
2008

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SB Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Zanotti SB Series

  • Page 1 CHEMA ELETTRICO IRING DIAGRAM CHEMA ELECTRIQUE CHALTPLAN SQUEMA ELECTRICO 50Hz SB - GM - ZM - AS - ZS - GS SPO - DBO - DBS RCV - RDV (Rotary) (Container) CUH - CUE - CUD - CUB - CUR - CUI 2008...
  • Page 4: Table Of Contents

    Indice schemi elettrici /Wiring diagram index / Index schemas electriques / Schaltplaneindex / Indice esquemas electricos INDICE / CONTENTS / INDEX / INHALTSVERZEICHNIS / INDICE MZM320T01F ....ZMN2001 MGS10602F ....GSP1001 MSB120TO02F ....81057LSB MZM212P01F ....ZMN1001 MGS10702F ....GSP1001 MSB125N02F ....81060LSB MZM213P01F ....
  • Page 5: Table Of Contents

    Indice schemi elettrici /Wiring diagram index / Index schemas electriques / Schaltplaneindex / Indice esquemas electricos INDICE / CONTENTS / INDEX / INHALTSVERZEICHNIS / INDICE MDB340NO02F ....AA10001 MDB340TO02F ....AA10001 RCV101002F ....... AC003 GCU1005H01F ....CUN1002 BDB121NO02F....27006DB RCV102002F ....... AC003 GCU1006H01F ....
  • Page 6 Indice schemi elettrici /Wiring diagram index / Index schemas electriques / Schaltplaneindex / Indice esquemas electricos INDICE / CONTENTS / INDEX / INHALTSVERZEICHNIS / INDICE HCU2050E01F ....... HCU3047D01F ....... HCU6220B01F ....... HCU2060E01F ....... HCU3050D01F ....... HCU6250B01F ....... HCU3075E01F ....... HCU3075D01F ....... HCU6300B01F .......
  • Page 7 Indice schemi elettrici /Wiring diagram index / Index schemas electriques / Schaltplaneindex / Indice esquemas electricos INDICE / CONTENTS / INDEX / INHALTSVERZEICHNIS / INDICE GCU2040I01F ........ GCU2060I01F ........ GCU4090I01F ........ GCU4125I01F ........ GCU5190I01F ........ GCU5250I01F ........ Pag.7...
  • Page 8 SUPPLY 230-220V/1N~/50-60Hz NB. EP SOLO NEI BSB (EP ONLY BSB) 2CU0829 CAVO LINEA VEDI DIS. TRANSFORMER COMPRESSOR EVAP.FANS DEFROST LIGHT ALARM ROOM NO NO LINE NEUTRAL GROUND RL1 RL2 NO NC NC NO COM NC NO 3 4 5 6 7 8 9 1 2 3 4 5 6 7 2CU0831...
  • Page 9 SUPPLY 230-220V/1N~/50-60Hz NB. EP SOLO NEI BSB o SE RICHIESTO IN VARIANTE (EP ONLY BSB or IF IN VARIANT CODE REQUIRED) 2CU0651 CAVO LINEA VEDI DIS. TRANSFORMER COMPRESSOR EVAP.FANS DEFROST LIGHT ALARM ROOM NO NO LINE NEUTRAL GROUND RL1 RL2 NO NC NC NO COM NC NO...
  • Page 10 SUPPLY N.B. : "EP" SOLO BSB 400V/3N~/50Hz (EP ONLY BSB) CAVO LINEA VEDI DIS. TRANSFORMER 2CU0809 COMPRESSOR EVAP.FANS DEFROST LIGHT ALARM ROOM NO NO LINE NEUTRAL GROUND RL1 RL2 NO NC NC NO COM NC NO 3 4 5 6 7 8 9 1 2 3 4 5 6 7 2CU0663...
  • Page 11 MSB235N 16A MSB235T 20A BSB235T 50A BSB235N 32A 230V/1N~/50Hz 400V/3N~/50Hz COMPRESSOR CONDENSER FAN EVAPORATOR FANS MSB235N I max.=8 A In=1x0,8A In=3x 0,7A MSB235T I max.=10 A BSB235T I max.=18 A BSB235N I max.=15 A MODELLO REV.nr. DISEGNO nr. FOGLIO nr : MSB235N02F-N02F/JEH-N180F-N350F BSB235T02F-351F-N02F-350F 81900LSB...
  • Page 12 DOOR MICROSWITCH TRANSFORMER COMPRESSOR EVAP.FANS DEFROST LIGHT ALARM ROOM NO NO LINE NEUTRAL GROUND RL1 RL2 NO NC NC NO COM NC NO 3 4 5 6 7 8 9 1 2 3 4 5 6 7 DOOR HEATER (only for "BSBS") DEFROST ROOM LIGHT...
  • Page 13: Mgm10302F

    LINEA (SUPPLY) 220-230V/1N~/50-60Hz LINE COM NO RL4 RL4 NEUTRAL C.S.I.R. MODELLO REV.nr. DISEGNO nr. FOGLIO nr : MGM10302F-02F/ABR-02F/ANG-02F/ANP MGM10378F/SAG-78F/SUR-97F GMP1002 MGM10302F/GDR-02F/INL-02F/MRL-02G-12F DATA: Approvato Disegnato Approvato DATA: MGM103161F-163F-21F-21F/CRS-40F Pedrazzoli Soncini 02-05-2006 MGM10354F-54F/ANM-54G-78F/ANG...
  • Page 14 LINEA (SUPPLY) 220-230V/1N~/50-60Hz SOLO SU GM2 SOLO SU GM2 ONLY ON GM2 ONLY ON GM2 LINE COM NO RL4 RL4 NEUTRAL GN D C.S.R. MODELLO REV.nr. DISEGNO nr. FOGLIO nr : MGM103... MGM110... BGM110... GMP1001 MGM105... MGM211... BGM112... DATA: Approvato Disegnato Approvato DATA:...
  • Page 15 UNITA' CONDENSATE AD ACQUA: MVC1 e MVC2 SONO ASSENTI NEGLI "MGM", MVC2 E' ASSENTE NEI "BGM2". WATER CONDENSED UNITS: MVC1 and MVC2 ARE NOT INCLUDED IN THE "MGM" UNITS, MVC2 IS NOT INCLUDED IN THE "BGM2" UNITS. LINEA (SUPPLY) 380-400V/3N~/50-60Hz SOLO SU GM2 SOLO SU GM2 ONLY ON GM2...
  • Page 16 CONDENSATORE SOLO SU GM3 CONDENSATORE SOLO SU GM3 * NOTA CAPACITOR ONLY ON GM3 CAPACITOR ONLY ON GM3 * NOTE * NOTA: * NOTE: UNITA' CONDENSATE AD ACQUA: LINEA (SUPPLY) MVC1 e MVC2 SONO ASSENTI NEGLI "MGM", 380-400V/3N~/50-60Hz MVC2 E' ASSENTE NEI "BGM2". SOLO SU GM2 SOLO SU GM2 WATER CONDENSED UNITS:...
  • Page 17 230V/1N~/50-60Hz XR 70CX "E1-ER1" SOLO SE RICHIESTO IN VARIANTE ("E1-ER1" ONLY IF IN VARIANT CODE REQUIRED) MODELLO REV.nr. DISEGNO nr. FOGLIO nr : MZM105T..MZM110T... MZM211T..MZM212P..MZM213P..ZMN1001 NUOVA ELETTRONICA BZM112T..BZM117T..BZM218T... BZM220P..DATA: Approvato Disegnato Approvato DATA: 08/01/2008 Soncini Soncini...
  • Page 18 400V/3N~/50-60Hz XR 70CX "E1-ER1" SOLO SE RICHIESTO IN VARIANTE ("E1-ER1" ONLY IF IN VARIANT CODE REQUIRED) MODELLO REV.nr. DISEGNO nr. FOGLIO nr : MZM212T..MZM213T..MZM315P..MZM320P..MZM320T..ZMN2001 NUOVA CENTRALINA BZM220T..BZM330P..BZM330T..DATA: Approvato Disegnato Approvato DATA: 08/01/2008 Soncini Soncini Soncini...
  • Page 19: Mas235T02F

    380-400-415V/3N~/50Hz 6,3A SWITCH: MORSETTIERA X1 = QUADRO ELETTRICO (X1 TERMINAL BOARD = ELECTRICAL CONTROL BOARD) MORSETTIERA X2 = SCATOLA CONNESSIONE MOTOVENTILATORI CONDENSATORE E EVAPORATORE (X2 TERMINAL BOARD = ELECTRICAL BOX FOR CONDENSER & EVAPORATOR MOTOR FANS) MORSETTIERA X3 = SCATOLA CONNESSIONE SOLENOIDI E RESISTENZA CARTER COMPRESSORE (X3 TERMINAL BOARD = ELECTRICAL BOX FOR SOLENOIDS &...
  • Page 20 TRANSFORMER LONG DISTANCE TELEVIS RS 485 ALARM EVAP. DEFROST LIGHT FANS ROOM COMPRESSOR COM NO RL4 RL4 BL-34 *ES solo su richiesta (*ES only on request) MODELLO REV.nr. DISEGNO nr. FOGLIO nr : BAS235T02F-/ANM/ELX/ARN/CRI/INL/SUR MAS235N02F-07F AS81751 BAS235N02F-69F-323F-325F-327F-341F-350F MAS235T02F/ANP-341F-524F-600F-607F-292F DATA: Approvato Disegnato Approvato DATA:...
  • Page 21: Mas335N02F

    380-400-415V/3N~/50Hz 6,3A BL-34 SWITCH: MORSETTIERA X1 = QUADRO ELETTRICO (X1 TERMINAL BOARD = ELECTRICAL CONTROL BOARD) MORSETTIERA X2 = SCATOLA CONNESSIONE MOTOVENTILATORI CONDENSATORE E EVAPORATORE (X2 TERMINAL BOARD = ELECTRICAL BOX FOR CONDENSER & EVAPORATOR MOTOR FANS) MORSETTIERA X3 = SCATOLA CONNESSIONE SOLENOIDI E RESISTENZA CARTER COMPRESSORE (X3 TERMINAL BOARD = ELECTRICAL BOX FOR SOLENOIDS &...
  • Page 22 TRANSFORMER LONG DISTANCE TELEVIS RS 485 ALARM EVAP. DEFROST LIGHT FANS ROOM COMPRESSOR COM NO RL4 RL4 GN D MODELLO REV.nr. DISEGNO nr. FOGLIO nr : MAS335N02F-N326F-N391F-N244F BAS335N02F-N07F-N325F AS81851 MAS335T02F-T07F-T152F-T161F-T350F-T380F BAS335N02F/INL-N02F/CRI-N325F/ANM DATA: Approvato Disegnato Approvato DATA: MAS335T02F/ELX-T383F-T600F BAS335T02F-T07F-T150F-T182F-T325F-T405F Soncini Pedrazzoli 05-12-2005 BAS335T02F/ANM-T607F...
  • Page 23: Mas340T02F

    380-400-415V/3N~/50Hz 6,3A BL-34 SWITCH: MORSETTIERA X1 = QUADRO ELETTRICO (X1 TERMINAL BOARD = ELECTRICAL CONTROL BOARD) MORSETTIERA X2 = SCATOLA CONNESSIONE MOTOVENTILATORI CONDENSATORE E EVAPORATORE (X2 TERMINAL BOARD = ELECTRICAL BOX FOR CONDENSER & EVAPORATOR MOTOR FANS) MORSETTIERA X3 = SCATOLA CONNESSIONE SOLENOIDI E RESISTENZA CARTER COMPRESSORE (X3 TERMINAL BOARD = ELECTRICAL BOX FOR SOLENOIDS &...
  • Page 24 TRANSFORMER LONG DISTANCE TELEVIS RS 485 ALARM EVAP. DEFROST LIGHT FANS ROOM COMPRESSOR COM NO RL4 RL4 GN D MODELLO REV.nr. DISEGNO nr. FOGLIO nr : BAS340T02F-T07F-T157F-T325F-T400F AS81860 MAS340T02F-T02F/ELX-T600F DATA: Approvato Disegnato Approvato DATA: MAS340T07F-T152F-T390F-T325F Pedrazzoli Soncini 05-12-2005...
  • Page 25 230V/1N~/50-60Hz XR 70CX "E1" SOLO SE RICHIESTO IN VARIANTE ("E1" ONLY IF IN VARIANT CODE REQUIRED) EVAPORATOR MODELLO REV.nr. DISEGNO nr. FOGLIO nr : MZS105T..MZS110T..MZS211T..MZS212P..MZS213P..ZSN1001 NUOVA CENTRALINA BZS112T..BZS117T..BZS218T..BZS220P..DATA: Approvato Disegnato Approvato DATA: 08/01/2008 Soncini...
  • Page 26 400V/3N~/50-60Hz XR 70CX "E1" SOLO SE RICHIESTO IN VARIANTE ("E1" ONLY IF IN VARIANT CODE REQUIRED) EVAPORATOR MODELLO REV.nr. DISEGNO nr. FOGLIO nr : MZS212T..MZS213T..MZS315P..MZS320P..MZS320T..ZSN2001 NUOVA CENTRALINA BZS220T..BZS330P..BZS330T..DATA: Approvato Disegnato Approvato DATA: 08/01/2008 Soncini Soncini...
  • Page 27 "ES" SOLO SU BGS O SU RICHIESTA EVAPORATORE REMOTO (REMOTE EVAPORATOR) "ES" ONLY ON BGS OR ON REQUEST LINEA (SUPPLY) 220-230V/1N~/50-60Hz cavo (cable)=3x0,5mmq ALL' EVAP. REM. DALL' UNITA' COND. (TO REM. EVAP.) (FROM COND. UNIT) cavo (cable)= 4x1,5mmq cavo (cable)=3x0,5mmq (BY-CLIENT) ATTENZIONE: PER UNITA' CON PREDISPOSIZIONE "LUCE-CELLA", EVAP.
  • Page 28 EVAPORATORE REMOTO (REMOTE EVAPORATOR) LINEA (SUPPLY) 220-230V/1N~/50-60Hz SOLO SU GS2 cavo (cable)=3x0,5mmq ONLY ON GS2 ALL' EVAP. REM. DALL' UNITA' COND. (TO REM. EVAP.) (FROM COND. UNIT) cavo (cable)= 4x1,5mmq cavo (cable)=3x0,5mmq (BY-CLIENT) ATTENZIONE: PER UNITA' CON PREDISPOSIZIONE "LUCE-CELLA", EVAP. LIGHT COMP.
  • Page 29 "ES" SOLO SU BGS O SU RICHIESTA CONDENSATORE SOLO SU GS3 EVAPORATORE REMOTO (REMOTE EVAPORATOR) UNITA' CONDENSATE AD ACQUA: "ES" ONLY ON BGS OR ON REQUEST CAPACITOR ONLY ON GS3 MVC1 e MVC2 SONO ASSENTI NEGLI "MGS", MVC2 E' ASSENTE NEI "BGS2". WATER CONDENSED UNITS: MVC1 and MVC2 ARE NOT INCLUDED IN THE "MGS"...
  • Page 30 "ES" SOLO SU BGS O SU RICHIESTA EVAPORATORE REMOTO (REMOTE EVAPORATOR) UNITA' CONDENSATE AD ACQUA: "ES" ONLY ON BGS OR ON REQUEST MVC1 e MVC2 SONO ASSENTI NEGLI "MGS", MVC2 E' ASSENTE NEI "BGS2". WATER CONDENSED UNITS: MVC1 and MVC2 ARE NOT INCLUDED IN THE "MGS" UNITS, MVC2 IS NOT INCLUDED IN THE "BGS2"...
  • Page 31 SUPPLY (BY-CLIENT) 220-230V/1N~/50-60Hz CAVO LINEA VEDI DIS. TRANSFORMER COMPRESSOR EVAP.FANS DEFROST LIGHT ALARM ROOM NO NO LINE NEUTRAL GROUND RL1 RL2 NO NC NC NO COM NC NO 3 4 5 6 7 8 9 1 2 3 4 5 6 7 2CU0800 2CU0663 2CU0802...
  • Page 32 SUPPLY (BY-CLIENT) 380-400V/3N~/50-60Hz CAVO LINEA VEDI DIS. TRANSFORMER COMPRESSOR EVAP.FANS DEFROST LIGHT ALARM ROOM NO NO LINE NEUTRAL GROUND RL1 RL2 NO NC NC NO COM NC NO 3 4 5 6 7 8 9 1 2 3 4 5 6 7 2CU0663 CAVO COMP.
  • Page 33 SUPPLY 230-220V/1N~/50-60Hz (BY-CLIENT) CAVO LINEA VEDI DIS. TRANSFORMER COMPRESSOR EVAP.FANS DEFROST LIGHT ALARM ROOM NO NO LINE NEUTRAL GROUND RL1 RL2 NO NC NC NO COM NC NO 3 4 5 6 7 8 9 1 2 3 4 5 6 7 2CU0800 2CU0663 2CU0802...
  • Page 34 SUPPLY (BY-CLIENT) 400-380V/3N~/50-60Hz CAVO LINEA VEDI DIS. 2CU0809 TRANSFORMER COMPRESSOR EVAP.FANS DEFROST LIGHT ALARM ROOM NO NO LINE NEUTRAL GROUND RL1 RL2 NO NC NC NO COM NC NO 3 4 5 6 7 8 9 1 2 3 4 5 6 7 2CU0663 2CU0800 CAVO COMP.
  • Page 35 220-230-240V/1N~/50Hz SWITCH: 380-400-415V/3N~/50Hz COMPRESSOR F5TK SPEED REGULATOR CONDENSER FAN HEU304D=SUPA 746 E (SIARCO) DEFROST HEATER EVAPORATOR FANS SOLO PER VARIANTE "463" (ONLY FOR "463" VARIANT) ES SOLO PER "BDB" O SE RICHIESTO IN VARIANTE EVAPORATOR (ES ONLY FOR "BDB" OR IF IN VARIANT CODE REQUIRED) MODELLO REV.nr.
  • Page 36 TRANSFORMER COMPRESSOR EVAP.FANS DEFROST LIGHT ALARM ROOM NO NO LINE NEUTRAL GROUND RL1 RL2 NO NC NC NO COM NC NO 3 4 5 6 7 8 9 1 2 3 4 5 6 7 H22 SOLO SE RICHIESTO IN VARIANTE (H22 ONLY IF IN VARIANT CODE REQUIRED) ER1 SOLO SE RICHIESTO IN VARIANTE (ER1 ONLY IF IN VARIANT CODE REQUIRED)
  • Page 37 CARATTERISTICHE GENERALI E ASSORBIMENTI MACCHINA COMPRESSORE SBRINAMENTO VENTOLA COND. VENTOLE EVAP. CAVO COMPRES. CAVO DI LINEA ( UNIT ) (COMPRESSOR) (DEFROST) (CONDEN. FAN) (EVAP. FANS) (COMPRES. CABLE) ( LINE CABLE ) MDB235NO... (GCD401NO...) MTZ32JF4=MT32JF4=5,9 A max. I max.=6,8 A In=0,73 A In tot.=1,24 A 4 x 1,5 mmq 5 x 1,5 mmq...
  • Page 38 220-230-240V/1N~/50Hz SWITCH: 380-400-415V/3N~/50Hz COMPRESSOR F5TK SPEED REGULATOR CONDENSER FAN DEFROST HEATER EVAPORATOR FANS ES SOLO PER "BDB" O SE RICHIESTO IN VARIANTE EVAPORATOR (ES ONLY FOR "BDB" OR IF IN VARIANT CODE REQUIRED) MODELLO REV.nr. DISEGNO nr. FOGLIO nr : MDB335NO...
  • Page 39 TRANSFORMER COMPRESSOR EVAP.FANS DEFROST LIGHT ALARM ROOM NO NO LINE NEUTRAL GROUND RL1 RL2 NO NC NC NO COM NC NO 3 4 5 6 7 8 9 1 2 3 4 5 6 7 ER1=RISCALDATORE QUADRO (OPTIONAL:SOLO SE RICHIESTO IN VARIANTE) MODELLO REV.nr.
  • Page 40 CARATTERISTICHE GENERALI E ASSORBIMENTI MACCHINA COMPRESSORE SBRINAMENTO VENTOLA COND. VENTOLE EVAP. CAVO COMPRES. CAVO DI LINEA ( UNIT ) (COMPRESSOR) (DEFROST) (CONDEN. FAN) (EVAP. FANS) (COMPRES. CABLE) ( LINE CABLE ) MDB335NO...F e MDB335NO...G MTZ50HK4=MT50HK4=12,0 A max. I max.=9,1 A In=2,3 A In tot.=1,86 A 4 x 2,5 mmq...
  • Page 41: Mdb340No02F

    220-230-240V/1N~/50Hz SWITCH: 380-400-415V/3N~/50Hz COMPRESSOR F5TK SPEED REGULATOR CONDENSER FAN DEFROST HEATER EVAPORATOR FANS EVAPORATOR MODELLO REV.nr. DISEGNO nr. FOGLIO nr : MDB340NO02F-86F-89F-152F-315F-316F-317F MDB340TO02F/FNV AA10001 MDB340N315F/ANP MDB340TO02F-86F-152F-316F-318F DATA: Approvato Disegnato Approvato DATA: GGCD631TO02F Soncini Soncini 04-04-2003...
  • Page 42 TRANSFORMER COMPRESSOR EVAP.FANS DEFROST LIGHT ALARM ROOM NO NO LINE NEUTRAL GROUND RL1 RL2 NO NC NC NO COM NC NO 3 4 5 6 7 8 9 1 2 3 4 5 6 7 MODELLO REV.nr. DISEGNO nr. FOGLIO nr : MDB340NO02F-86F-89F-152F-315F-316F-317F MDB340TO02F/FNV AA10001...
  • Page 43 CARATTERISTICHE GENERALI E ASSORBIMENTI MACCHINA COMPRESSORE SBRINAMENTO VENTOLA COND. VENTOLE EVAP. CAVO COMPRES. CAVO DI LINEA ( UNIT ) (COMPRESSOR) (DEFROST) (CONDEN. FAN) (EVAP. FANS) (COMPRES. CABLE) ( LINE CABLE ) MDB340NO...F e MDB340NO...G MTZ80HP4=MT80HP4=23,0 A max. I max.=10,9 A In=2,65 A In tot.=2,19 A 4 x 4,0 mmq...
  • Page 44: Bdb235To02F

    220-230-240V/1N~/50Hz SWITCH: 380-400-415V/3N~/50Hz COMPRESSOR F5TK SPEED REGULATOR CONDENSER FAN DEFROST HEATER EVAPORATOR FANS EVAPORATOR MODELLO REV.nr. DISEGNO nr. FOGLIO nr : BDB235NO368F BDB235TO02F-02F/ANP-152F-186F-195F-212F AA08002 BDB235NO468F/ANP BDB235TO296F-315F-317F/ANM-86F-151F DATA: Approvato Disegnato Approvato DATA: Soncini Soncini 04-04-2003...
  • Page 45 TRANSFORMER COMPRESSOR EVAP.FANS DEFROST LIGHT ALARM ROOM NO NO LINE NEUTRAL GROUND RL1 RL2 NO NC NC NO COM NC NO 3 4 5 6 7 8 9 1 2 3 4 5 6 7 MODELLO REV.nr. DISEGNO nr. FOGLIO nr : BDB235NO368F BDB235TO02F-02F/ANP-152F-186F-195F-212F AA08002...
  • Page 46 CARATTERISTICHE GENERALI E ASSORBIMENTI MACCHINA COMPRESSORE SBRINAMENTO VENTOLA COND. VENTOLE EVAP. CAVO COMPRES. CAVO DI LINEA ( UNIT ) (COMPRESSOR) (DEFROST) (CONDEN. FAN) (EVAP. FANS) (COMPRES. CABLE) ( LINE CABLE ) BDB235NO368F MTZ80HP4=23,0 A max. I max.=6,8 A In=2,3 A In tot.=1,24 A 4 x 4 mmq 5 x 6 mmq...
  • Page 47: Bdb340No02F

    220-230-240V/1N~/50Hz SWITCH: 380-400-415V/3N~/50Hz COMPRESSOR F5TK SPEED REGULATOR CONDENSER FAN DEFROST HEATER EVAPORATOR FANS EVAPORATOR MODELLO REV.nr. DISEGNO nr. FOGLIO nr : BDB340TO02F-298F-315F-TO311F/ANP AA10002 BDB340NO02F-86F-305F-315F/ANP DATA: Approvato Disegnato Approvato DATA: HCD631NO02F Soncini Soncini 04-04-2003...
  • Page 48 TRANSFORMER COMPRESSOR EVAP.FANS DEFROST LIGHT ALARM ROOM NO NO LINE NEUTRAL GROUND RL1 RL2 NO NC NC NO COM NC NO 3 4 5 6 7 8 9 1 2 3 4 5 6 7 MODELLO REV.nr. DISEGNO nr. FOGLIO nr : BDB340TO02F-298F-315F-TO311F/ANP AA10002 BDB340NO02F-86F-305F-315F/ANP...
  • Page 49 CARATTERISTICHE GENERALI E ASSORBIMENTI MACCHINA COMPRESSORE SBRINAMENTO VENTOLA COND. VENTOLE EVAP. CAVO COMPRES. CAVO DI LINEA ( UNIT ) (COMPRESSOR) (DEFROST) (CONDEN. FAN) (EVAP. FANS) (COMPRES. CABLE) ( LINE CABLE ) BDB340NO...F S1051Y=21,0 A I max.=10,9 A In=2,65 A In tot.=2,19 A 4 x 4,0 mmq 5 x 6,0 mmq BDB340TO...F...
  • Page 50: Mdb235Ts02F

    220-230-240V/1N~/50Hz SWITCH: 380-400-415V/3N~/50Hz "N" I max.=7,2 A "T" I max.=8,85 A COMPRESSOR In= 0,64 A SPEED REGULATOR CONDENSER FAN I max.= 6,8 A In tot.= 1,24 A DEFROST HEATER EVAPORATOR FANS EVAPORATOR MODELLO REV.nr. DISEGNO nr. FOGLIO nr : MDB235NS02F-NS446F 7DB235NS02F AB08001 MDB235NS237F...
  • Page 51 TRANSFORMER COMPRESSOR EVAP.FANS DEFROST LIGHT ALARM ROOM NO NO LINE NEUTRAL GROUND RL1 RL2 NO NC NC NO COM NC NO 3 4 5 6 7 8 9 1 2 3 4 5 6 7 In presence of "FGS", remove the link MODELLO REV.nr.
  • Page 52 CONDENSING UNIT EVAPORATOR FROM X1 TO X3 FROM X1 TO X2 FROM X1 TO X2 MODELLO REV.nr. DISEGNO nr. FOGLIO nr : MDB235NS02F-NS446F 7DB235NS02F AB08001 MDB235NS237F 7DB235TS02F DATA: Approvato Disegnato Approvato DATA: MDB235TS02F GCD401TS02F Soncini Soncini 15-04-2003...
  • Page 53: Mdb335Ns02F

    220-230-240V/1N~/50Hz SWITCH: 380-400-415V/3N~/50Hz "ZS" I max=8,19 A "ZB" I max=10,3 A COMPRESSOR In=0,64 A SPEED REGULATOR CONDENSER FAN I max.=9,1 A In tot.=1,86 A DEFROST HEATER EVAPORATOR FANS EVAPORATOR MODELLO REV.nr. DISEGNO nr. FOGLIO nr : MDB335NS02F AB09002 "BVR" nel quadro MDB335NS315F DATA: Approvato...
  • Page 54 TRANSFORMER COMPRESSOR EVAP.FANS DEFROST LIGHT ALARM ROOM NO NO LINE NEUTRAL GROUND RL1 RL2 NO NC NC NO COM NC NO 3 4 5 6 7 8 9 1 2 3 4 5 6 7 In presence of "FGS", remove the link MODELLO REV.nr.
  • Page 55 CONDENSING UNIT EVAPORATOR FROM X1 TO X3 FROM X1 TO X2 FROM X1 TO X2 MODELLO REV.nr. DISEGNO nr. FOGLIO nr : MDB335NS02F AB09002 Rivista morsettiera "X1" MDB335NS315F DATA: Approvato Disegnato Approvato DATA: MDB335NS02F/JEH 03-10-2006 SONCINI Soncini Soncini 16-04-2003...
  • Page 56: Mdb335Ts02F

    220-230-240V/1N~/50Hz SWITCH: 380-400-415V/3N~/50Hz "ZS" I max=10,7 A "ZB" I max=12,8 A COMPRESSOR In=0,64 A In=0,64 A SPEED REGULATOR CONDENSER CONDENSER I max.=9,1 A In tot.=1,86 A FAN n°1 FAN n°2 DEFROST HEATER EVAPORATOR FANS EVAPORATOR MODELLO REV.nr. DISEGNO nr. FOGLIO nr : MDB335TS02F 7DB335TS02F AB09003...
  • Page 57 TRANSFORMER COMPRESSOR EVAP.FANS DEFROST LIGHT ALARM ROOM NO NO LINE NEUTRAL GROUND RL1 RL2 NO NC NC NO COM NC NO 3 4 5 6 7 8 9 1 2 3 4 5 6 7 In presence of "FGS", remove the link MODELLO REV.nr.
  • Page 58 CONDENSING UNIT EVAPORATOR RIGHT FROM X1 FROM X1 TO X3 TO X2 FROM X1 TO X2 LEFT MODELLO REV.nr. DISEGNO nr. FOGLIO nr : MDB335TS02F 7DB335TS02F AB09003 "BVR" nel quadro MDB335TS161F DATA: Approvato Disegnato Approvato DATA: MDB335TS267F 28-03-2005 SONCINI Varvella Soncini 16-04-2003 MDB335TS316F...
  • Page 59: Mdb340Ns02F

    220-230-240V/1N~/50Hz SWITCH: 380-400-415V/3N~/50Hz I max=13,6 A COMPRESSOR In=0,64 A In=0,64 A SPEED REGULATOR CONDENSER CONDENSER I max.=10,9 A In tot.=3x0,73 A FAN n°1 FAN n°2 DEFROST HEATER EVAPORATOR FANS EVAPORATOR MODELLO REV.nr. DISEGNO nr. FOGLIO nr : MDB340NS02F 7DB340NS02F AB10002 "BVR"...
  • Page 60 TRANSFORMER COMPRESSOR EVAP.FANS DEFROST LIGHT ALARM ROOM NO NO LINE NEUTRAL GROUND RL1 RL2 NO NC NC NO COM NC NO 3 4 5 6 7 8 9 1 2 3 4 5 6 7 In presence of "FGS", remove the link MODELLO REV.nr.
  • Page 61 CONDENSING UNIT EVAPORATOR RIGHT FROM X1 FROM X1 TO X3 TO X2 FROM X1 TO X2 LEFT MODELLO REV.nr. DISEGNO nr. FOGLIO nr : MDB340NS02F 7DB340NS02F AB10002 "BVR" nel quadro MDB340NS151F DATA: Approvato Disegnato Approvato DATA: MDB340NS317F 28-03-2005 SONCINI Soncini Soncini 16-04-2003...
  • Page 62: Mdb340Ts02F

    220-230-240V/1N~/50Hz SWITCH: 380-400-415V/3N~/50Hz I max=15,4 A COMPRESSOR In=0,64 A In=0,64 A SPEED REGULATOR CONDENSER CONDENSER I max.=10,9 A In tot.=3x0,73 A FAN n°1 FAN n°2 DEFROST HEATER EVAPORATOR FANS EVAPORATOR MODELLO REV.nr. DISEGNO nr. FOGLIO nr : MDB340TS02F AB10003 "BVR" nel quadro MDB340TS161F DATA: Approvato...
  • Page 63 TRANSFORMER COMPRESSOR EVAP.FANS DEFROST LIGHT ALARM ROOM NO NO LINE NEUTRAL GROUND RL1 RL2 NO NC NC NO COM NC NO 3 4 5 6 7 8 9 1 2 3 4 5 6 7 F1TR MODELLO REV.nr. DISEGNO nr. FOGLIO nr : MDB340TS02F AB10003...
  • Page 64 CONDENSING UNIT EVAPORATOR RIGHT FROM X1 FROM X1 TO X3 TO X2 FROM X1 TO X2 LEFT MODELLO REV.nr. DISEGNO nr. FOGLIO nr : MDB340TS02F AB10003 "BVR" nel quadro MDB340TS161F DATA: Approvato Disegnato Approvato DATA: MDB340TS170F/ELX 28-03-2005 SONCINI Soncini Soncini 16-04-2003...
  • Page 65: Bdb235Ts02F

    "T" 32A "N" 25A 220-230-240V/1N~/50Hz SWITCH: 380-400-415V/3N~/50Hz "N" I max.=10,7 A "T" I max.=13,8 A COMPRESSOR In=0,64 A SPEED REGULATOR CONDENSER FAN I max.=6,8 A In tot.=1,24 A DEFROST HEATER EVAPORATOR FANS EVAPORATOR MODELLO REV.nr. DISEGNO nr. FOGLIO nr : BDB235NS02F AB08002 BDB235NS02F/ANM...
  • Page 66 TRANSFORMER COMPRESSOR EVAP.FANS DEFROST LIGHT ALARM ROOM NO NO LINE NEUTRAL GROUND RL1 RL2 NO NC NC NO COM NC NO 3 4 5 6 7 8 9 1 2 3 4 5 6 7 In presence of "FGS", remove the link MODELLO REV.nr.
  • Page 67 CONDENSING UNIT EVAPORATOR FROM X1 TO X3 FROM X1 TO X2 FROM X1 TO X2 MODELLO REV.nr. DISEGNO nr. FOGLIO nr : BDB235NS02F AB08002 BDB235NS02F/ANM DATA: Approvato Disegnato Approvato DATA: BDB235NS316F Soncini Soncini 15-04-2003 BDB235TS02F...
  • Page 68: Bdb335Ns02F

    40A ("N") 50A ("T") 220-230-240V/1N~/50Hz SWITCH: 380-400-415V/3N~/50Hz "N" I max=16,1 A "T" I max=22,3 A COMPRESSOR In=0,64A In=0,64A SPEED REGULATOR CONDENSER CONDENSER I max.=9,1 A In tot.=1,86 A FAN n°1 FAN n°2 DEFROST HEATER EVAPORATOR FANS EVAPORATOR MODELLO REV.nr. DISEGNO nr. FOGLIO nr : BDB335NS02F BDB335NS170F/ELX...
  • Page 69 TRANSFORMER COMPRESSOR EVAP.FANS DEFROST LIGHT ALARM ROOM NO NO LINE NEUTRAL GROUND RL1 RL2 NO NC NC NO COM NC NO 3 4 5 6 7 8 9 1 2 3 4 5 6 7 F1TR MODELLO REV.nr. DISEGNO nr. FOGLIO nr : BDB335NS02F BDB335NS170F/ELX...
  • Page 70 CONDENSING UNIT EVAPORATOR RIGHT FROM X1 FROM X1 TO X3 TO X2 FROM X1 TO X2 LEFT MODELLO REV.nr. DISEGNO nr. FOGLIO nr : BDB335NS02F BDB335NS170F/ELX AB09001 "BVR" nel quadro BDB335TS02F BDB335TS170F/ELX DATA: Approvato Disegnato Approvato DATA: BDB335TS310F 28-03-2005 SONCINI SONCINI SONCINI 16-04-2003...
  • Page 71: Bdb340Ns02F

    50A ("N") 63A ("T") 220-230-240V/1N~/50Hz SWITCH: 380-400-415V/3N~/50Hz "N" I max.=25,1 A "T" I max.=30,6 A COMPRESSOR In=0,64A In=0,64A SPEED REGULATOR CONDENSER CONDENSER I max.=10,9 A In tot.=2,4 A FAN n°1 FAN n°2 DEFROST HEATER EVAPORATOR FANS EVAPORATOR MODELLO REV.nr. DISEGNO nr. FOGLIO nr : BDB340NS02F BDB340NS170F/ELX...
  • Page 72 TRANSFORMER COMPRESSOR EVAP.FANS DEFROST LIGHT ALARM ROOM NO NO LINE NEUTRAL GROUND RL1 RL2 NO NC NC NO COM NC NO 3 4 5 6 7 8 9 1 2 3 4 5 6 7 F1TR MODELLO REV.nr. DISEGNO nr. FOGLIO nr : BDB340NS02F BDB340NS170F/ELX...
  • Page 73 CONDENSING UNIT EVAPORATOR RIGHT FROM X1 FROM X1 TO X3 TO X2 FROM X1 TO X2 LEFT MODELLO REV.nr. DISEGNO nr. FOGLIO nr : BDB340NS02F BDB340NS170F/ELX AB10001 "BVR" nel quadro BDB340TS02F BDB340TS170F/ELX DATA: Approvato Disegnato Approvato DATA: BDB340NS161F 28-03-2005 SONCINI Soncini Soncini 16-04-2003...
  • Page 74 230V/1N~/50Hz XH240L Supply Comp Caldo 2CU0860 2CU0859 NOTE LEGENDA PMX PRESENTE SOLO SULLE UNITA' M1=MOTORE COMPRESSORE CON VAR. "10" o COND. AD ACQUA MVC=MOTORE VENTOLE CONDENSATORE MVE=MOTORE VENTOLE EVAPORATORE F1=FUSIBILE COMPRESSORE F1E=CENTRALINA ELETTRONICA FUM=TERMOSATO UMIDIFICA FSC=TERMOSATAO SICUREZZA CALDO MVC ASSENTE NELLE MACCHINE CONDENSATE E0=RESISTENZE CALDO AD ACQUA...
  • Page 75: Rcv201002F

    230V/1N~/50Hz XH240L Supply Comp Caldo 2CU0860 2CU0859 LEGENDA M1=MOTORE COMPRESSORE MVC=MOTORE VENTOLE CONDENSATORE MVE=MOTORE VENTOLE EVAPORATORE F1=FUSIBILE COMPRESSORE F1E=CENTRALINA ELETTRONICA FUM=TERMOSATO UMIDIFICA FSC=TERMOSATAO SICUREZZA CALDO E0=RESISTENZE CALDO EUM=RESISTENZE UMIDIFICA BTU=SONDA UMIDITA' BA=SONDA TEMPERATURA YUM=SOLENOIDE ACQUA MODELLO REV.nr. DISEGNO nr. FOGLIO nr : RCV201002F-102F-050F-051F AC004 RCV202002F-102F...
  • Page 76 230V/1N~/50Hz LEGENDA M1=MOTORE COMPRESSORE MVC=MOTORE VENTOLE CONDENSATORE MVE=MOTORE VENTOLE EVAPORATORE XH240L F1=FUSIBILE COMPRESSORE F1E=CENTRALINA ELETTRONICA FUM=TERMOSATO UMIDIFICA Supply Comp Caldo FSC=TERMOSATAO SICUREZZA CALDO E0=RESISTENZE CALDO EUM=RESISTENZE UMIDIFICA 2CU0858 BTU=SONDA UMIDITA' BA=SONDA TEMPERATURA 2CU0853 YUM=SOLENOIDE ACQUA PMX=PRESSOSTATO DI MAX (SOLO SU RICHIESTA) E1=RESISTENZA CARTER (SOLO SU RICHIESTA) EVAPORATORE...
  • Page 77: Rdv201002F

    230V/1N~/50-60Hz LEGENDA M1=MOTORE COMPRESSORE MVC=MOTORE VENTOLE CONDENSATORE MVE=MOTORE VENTOLE EVAPORATORE XH240L F1=FUSIBILE COMPRESSORE F1E=CENTRALINA ELETTRONICA FUM=TERMOSATO UMIDIFICA Supply Comp Caldo FSC=TERMOSATAO SICUREZZA CALDO E0=RESISTENZE CALDO EUM=RESISTENZE UMIDIFICA 2CU0858 BTU=SONDA UMIDITA' 2CU0853 BA=SONDA TEMPERATURA YUM=SOLENOIDE ACQUA PMX=PRESSOSTATO DI MASS. (OPTIONAL) E1=RES. PRERISCALDO (OPTIONAL) EVAPORATORE MODELLO REV.nr.
  • Page 78: Mas123T443S

    230V/1N~/50Hz XR 70CX DOOR MICROSWITCH ROOM LIGHT *E1 ASSENTE PER MACCHINE CON VARIANTE "568" *YG ASSENTE PER MACCHINE CON VARIANTE "554" (*E1 DO NOT PRESENT FOR UNITS WITH "568" VARIANT) (*YG DO NOT PRESENT FOR UNITS WITH "554" VARIANT) MODELLO REV.nr.
  • Page 79 MACCHINA COMPRESSORE VENTOLA COND. (UNIT) (COMPRESSOR) (CONDENSER FAN) GCU1005H... NE9213GK/CSR I max.=3,64 A n°1 FAN In=1x0,29 A GCU1006H... CAJ9480Z/F/CSR I max.=6,6 A n°1 FAN In=1x0,29 A GCU1007H... CAJ9510Z/F/CSR I max.=7,1 A n°1 FAN In=1x0,29 A GCU1010H... CAJ9513Z/F/CSR I max.=10,1 A n°1 FAN In=1x0,29 A GCU1012H...
  • Page 80 MACCHINA COMPRESSORE VENTOLA COND. (UNIT) (COMPRESSOR) (CONDENSER FAN) GCU2018H... MTZ22JC4 I max.=6 A n°1 FAN In=1x0,62 A GCU2023H... MTZ28JE4 I max.=7,5 A n°1 FAN In=1x0,62 A GCU2027H... MTZ32JF4 I max.=8 A n°1 FAN In=1x0,62 A GCU2035H... MTZ40JH4 I max.=10 A n°1 FAN In=1x0,62 A COMPRESSOR...
  • Page 81 MACCHINA COMPRESSORE VENTOLA COND. (UNIT) (COMPRESSOR) (CONDENSER FAN) GCU3040H... MTZ50HK4 I max.=12 A n°2 FAN In=2x0,62 A GCU3050H... MTZ64HM4 I max.=15 A n°2 FAN In=2x0,62A COMPRESSOR CONDENSER CONDENSER H/P SWITCH L/P SWITCH HCU3040H... NTZ136A4 I max.=14,3 A n°2 FAN In=2x0,62 A FAN n°1 FAN n°2 MODELLO...
  • Page 82 MACCHINA COMPRESSORE VENTOLA COND. (UNIT) (COMPRESSOR) (CONDENSER FAN) GCU5065H... MTZ80HP4 I max.=18 A n°4 FAN In=4x0,62 A GCU5085H... MTZ100HS4 I max.=22 A n°4 FAN In=4x0,62 A GCU5100H... MTZ125HU4 I max.=27 A n°4 FAN In=4x0,62 A GCU5130H... MTZ160HW4 I max.=36 A n°4 FAN In=4x0,62 A COMPRESSOR CONDENSER...
  • Page 83 MACCHINA COMPRESSORE VENTOLA COND. (UNIT) (COMPRESSOR) (CONDENSER FAN) C.S.R. COMPRESSOR CONDENSER FAN H/P SWITCH L/P SWITCH COMPRESSOR HCU1020H... FH2480Z/F/CSR I max.=19,2 A n°1 FAN In=1x0,29 A CRANKCASE HEATER MODELLO REV.nr. DISEGNO nr. FOGLIO nr : CONDENSING UNITS MONOPHASES CUN1003 UNITA' CONDENSATRICI MONOFASI DATA: Approvato Disegnato...
  • Page 84 MACCHINA COMPRESSORE VENTOLA COND. (UNIT) (COMPRESSOR) (CONDENSER FAN) COMPRESSOR CONDENSER CONDENSER H/P SWITCH L/P SWITCH FAN n°1 FAN n°2 HCU4075H... NTZ215A4 I max.=22,3 A n°2 FAN In=2x0,62 A HCU4085H... NTZ271A4 I max.=27 A n°2 FAN In=2x0,62 A MODELLO REV.nr. DISEGNO nr. FOGLIO nr : CONDENSING UNITS CUN4002...
  • Page 86 ZANOTTI S.p.A. 46029 Pegognaga (MN) Italy Via M. L. King, 30 Tel. +39 0376 5551 - Fax. +39 0376 536554 site web: www.zanotti.com e-mail: info@zanotti.com...