Displaying The Temperature Chart - Zanotti DFZ Use And Maintenance Instructions

Table of Contents

Advertisement

In this mask, you can see for how many hours the oil and oil filter have been
used, as well as the total working hours of the diesel engine and electric motor.
When the oil or oil filter have been used for over a limit number of hours, the sym-
bol
will be displayed on the main mask; then, accessing the maintenance
mask the icons
or
will be displayed, to show that either the oil needs
changing or the oil filter element needs replacing.
To reset this warning signal, just press the key found by these icons for a few
seconds.
GB
GB

4.7 Displaying the temperature chart

By pressing key
you can access the mask below which allows displaying the
temperature history record. By pressing key
you can display the first 12
hours of the current day, the second 12 hours, or the recording of whole day. By
pressing keys
and
you can move the cursor to see the temperature
recorded at a specific time of day.
By pressing push button
you can go to the 24 hours previous to those dis-
played.