Connecting To Remote 14 Receptacle Rc14 - Red-D-Arc D55OK HO Owner's Manual

Cc/cv dc diesel welder
Table of Contents

Advertisement

5-13. Connecting To Remote 14 Receptacle RC14

*The remaining sockets are not used.
OR
804 582-A
Socket*
A
24 VOLTS AC
B
C
D
REMOTE
OUTPUT
CONTROL
E
I
115 VOLTS AC
J
K
GND
NEUTRAL
G
Socket Information
24 volts AC. Protected by
supplementary protector CB5.
Contact closure to A completes
24 volt AC contactor control
circuit.
Output to remote control:+10
volts DC in MIG or Stick mode;
0 to +10 volts DC in TIG mode.
Remote control circuit common.
DC input command signal: 0 to
+10 volts from min. to max. of
remote control with Voltage/
Amperage Adjust control at
max.
115 volts, 10 amperes, 60 Hz
AC. Protected by supplementa-
ry protector CB13.
Contact closure to I completes
115 volt AC contactor control
circuit.
Chassis common.
Circuit common for 24 and 115
volt AC circuit.
OM-243 907 Page 29