Options
*Factory Installed Options
7,3
2" Pleated Filters
Black Epoxy Pre-Coated Coils
Dehumidification Option
Differential Pressure Switches
High Efficiency Motors
Hinged Access Doors
Novar Return Air Sensor
8
Novar Unit Controls
Powered or Unpowered
6
Convenience Outlet
Stainless Steel Heat Exchanger
with 10-year warranty
Supply and/or Return Air Smoke
4,13
Detector
Thermal Expansion Valve
Through the Base Electrical
Access
Through the Base Electrical with
14,15
Circuit Breaker
Through the Base Electrical with
10,14,15
Disconnect Switch
Factory* or Field Installed Options
Barometric Relief
Clogged Filter/Fan Failure
4,7
Switch
Discharge Air Sensing Kit
Economizer (Downflow)
7,11,15
Electric Heaters
3,4,7
Frostat
LonTalk® Communications
7
Interface (LCI)
7
Oversized Motors
Reference or Comparative
Enthalpy
7
Tool-less Hail Guards
Trane Communications Interface
2,7
(TCI)
Field Installed Options
CO
Sensing
2
Digital Display Zone Sensor
Dual Thermistor Remote Zone
Sensor
Economizer (Horizontal)
High Altitude Kit
RT-PRC024-EN
Model Number Description
High and Low Static Drive Kits
Humidity Sensor
17
Low Static Drive
LP Conversion Kit
7
Manual Outside Air Damper
3,14,16
Motorized Outside Air Dampers
Powered Exhaust
7
Quick Start Kit
ReliaTel Options Module
9
Remote Potentiometer
Roof Curb (Downflow Only)
Thermostat
Ventilation Override Accessory
7
Zone Sensors and Remote Zone
Sensors

Model Number Notes

16
1.
Some field set up required.
2.
TCI is for use with non-VariTrac
systems and VariTrac systems.
3.
All 10th digit model numbers
including reheat coil (M,N,P ,R)
require additional factory
installed options;
17
ReliaTel™options module,
Frostat, and 2" pleated filters.
4.
Requires ReliaTel options
module.
5.
Requires Economizer.
4,7
6.
Must be ordered with Through-
1
the-Base Electrical and either
Unit Mounted Disconnect or
Circuit Breaker.
7.
Available factory installed on
downflow AND horizontal units.
Verify with ordering system.
8.
The Novar control option
5,7
includes the following factory
installed and wired devices:
Novar ETM-2024 or Novar 3051
rooftop controller, fan proving
switch, clogged filter or unit
shutdown switch, Cool 1, Cool 2,
Heat switch and discharge air
sensor (Novar 2024 is downflow
only).
Note: Option cannot be
12
4
ordered in conjunction
with FIOPS Smoke
Detector option.
9.
This option consists of the Novar
return air sensor (Novar #WTS-
10) that is wired and shipped in
the return air section of the unit.
The sensor ships with
approximately 15' of extra wire
for dropping down the return air
duct (downflow only).
10. Cannot be fused.
11. Must be factory installed when
using Through-the-Base Options.
12. ReliaTel Options Module is
required when ordering the
following accessories: Clogged
Filter Switch, Fan Fail Switch,
Discharge Air Sensing Kit,
Frostat, Ventilation Override,
Smoke Detector and
Dehumidification.
13. Option cannot be ordered in
conjunction with field installed
economizer on downflow units.
Must be factory installed. The
return air smoke detector may
not fit up or work properly on the
Voyager units when used in
conjunction with 3rd party
accessories (such as bolt on heat
wheels, economizers, and power
exhaust). Do not order the return
air smoke detectors when using
this type of accessory.
14. Unit mounted disconnect and
circuit breakers are mutually
exclusive of each other.
15. Through-the-base electrical
option must be ordered with
either unit mounted disconnect
or circuit breaker. When adding
heat, must order Trane Electric
Heat.
16. Available on high efficiency,
downflow units only.
17. All Factory Installed Options are
Built-to-Order. Check order
services for estimated
production cycle.
Note: *Some Factory Installed
Options (FIOPS) available for
Downflow Air Discharge units
only. Please verify with
ordering system for
availability.
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Voyager yc*Voyager tc seriesVoyager yc series

Table of Contents