R-410A System Charging Procedure - York H4AH024S06 Technical Manual

R-410a 12 seer split-system air conditioners
Table of Contents

Advertisement

R-410A SYSTEM CHARGING PROCEDURE

ADDITIONAL R-410A CHARGE / ORIFICE SIZE FOR VARIOUS MATCHED SYSTEMS
OUTDOOR UNIT
1
UNIT ORIFICE(S)
FACTORY CHARGE, LBS. - OZ.
INDOOR COIL
G1FA/G1UA024S14 ,17
G1FA/G1UA030S14
G1FA/G1UA036S14, 17, 21
G1FA/G1UA048S17
G1FA/G1UA048S21
G1FA/G1UA060S21, 24
G2FD024(S,H)14, 17
G2FD030(S,H)17
G2FD035(S,H)14
G2FD036(S,H)17, 21
G2FD042(S,H)21
G2FD046(S,H)17
G2FD048(S,H)21, 24
G2FD060(S,H)24
G2FD061H24
G1HD024
G1HD036
G1HD048
G1HD060
F2RC/F2FC024
F2RC/F2FC030
F2RC/F2FC036
F2RP/F2FP024
F2RP/F2FP030
F2RP/F2FP036
F2FP040
F2RP/F2FP042
F2FP045
F2RP/F2FP048
F2RP/F2FP060
F2FV060
REFRIGERANT LINE ADDER OZ./FT.
1 These orifices are packed in the instruction/warranty packet of each outdoor unit.
2 These orifices are factory mounted in the flow control device of each indoor coil.
Unitary Products Group
H4AH024
53
5 - 5
2
COIL ORIFICE
59
55 + 0
65
55 + 2
73
51 + 4
84
-
84
-
90
-
61
55 + 0
65
55 + 4
65
55 + 4
75
55 + 2
78
-
78
-
84
-
90
-
90
-
59
55 + 0
69
55 + 7
84
-
96
-
61
-
65
55 + 2
73
-
61
55 + 0
65
55 + 4
75
-
63
-
78
-
78
-
84
-
90
-
90
-
0.67
H4AH030
H4AH036
61
65, 67
6 - 5
7 - 2
REQUIRED SYSTEM ORIFICE + ADDITIONAL CHARGE, OZ.
-
-
61 + 0
-
61 + 2
65 + 0
-
67 + 20
-
67 + 20
-
-
-
-
61 + 2
-
61 + 2
61 + 7
65 + 0
-
65 + 5
-
65 + 5
-
67 + 13
-
-
-
-
-
-
61 + 7
65 + 10
-
67 + 13
-
-
-
-
-
-
61 + 2
-
-
-
61 + 2
-
61 + 7
65 + 0
-
-
-
65 + 5
-
-
-
67 + 13
-
-
-
-
0.67
0.67
036-21215-003 Rev. B (1202)
H4AH042
H4AH048
69, 71
75, 77
8 - 5
7 - 7
-
-
-
-
-
-
69 + 10
75 + 8
69 + 10
75 + 8
71 + 13
77 + 11
-
-
-
-
-
-
-
-
69 + 10
-
69 + 10
75 + 8
69 + 12
75 + 10
71 + 15
77 + 13
-
77 + 18
-
-
-
-
69 + 9
75 + 0
-
77 + 6
-
-
-
-
-
-
-
-
-
-
-
-
-
-
69 + 10
-
-
-
69 + 12
75 + 10
-
77 + 13
-
77 + 13
0.7
0.7
H4AH060
87
9 - 5
-
-
-
-
-
84 + 0
-
-
-
-
-
-
-
84 + 0
84 + 9
-
-
-
84 + 0
-
-
-
-
-
-
-
-
-
-
84 + 0
84 + 0
0.7
3