Features and Specifications

List of sub-assemblies
A89WS-AN1, AN2
Direction Sensor range: 0 – 360 degrees.
Direction Accuracy:
Speed Sensor range:
Speed Accuracy:
Operating temperature:
A89WS-PY1
Sensor range:
Accuracy:
Operating temperature:
A89WS-TC1, TC2
Sensor range:
Accuracy:
Operating temperature:
A89WS-TH1
Temp Sensor range:
Temp Accuracy:
Humidity Sensor range: 0 ~ 100 % Relative Humidity
Humidity Accuracy:
Operating temperature:
A89WS-TO1
Sensor range:
Accuracy:
Operating temperature:
YWX0431, YWX0432
Control Box
Operating Temperature: -30 ~ +50c, 0-95% RH, non-condensing.
Power Supply:
Power input:
Operating temperature:
IO module:
Accuracy:
Operating temperature:
Protocol:
Page 7
Anemometer kit
Azimuth: 360
o
+/- 3º
0 – 100 MPH.
Gusts up to 220 MPH
1 mph or +/- 3%
-50C ~ +50C
Pyranometer kit
0 ~ 1400W/m
2
+/- 5%
-40 ~ +65C
Cell Temperature Kit
-13 ~ +221F.
10K Type 2 resistive sensor.
+/- 1.8°C typical; +/- 3.0°C max. over 0° to 70°C
-25 ~ +125C
Air Temperature and Humidity Probe.
-40 ~ +122 degrees Fahrenheit
+/-1 degree F
+/- 2% (
replaceable sensor)
-40 ~ +122
Air Temperature Probe.
-40 ~ +122 degrees Fahrenheit
+/-1 degree F
-40 ~ +122
weather station Control Box
Weidmuller 8739140000
120-240VAC, 24W, 50-60Hz
-10 ~ +70c
A8332-8F2D
+/- 0.25% (4-20mA mode inputs) +/- 1% for cell temperature sensor (resistive mode inputs)
-30 ~ +70c
Modbus/RTU, RS-485, 9600, N81
mechanical, 355
o
electrical (5
o
open) 360
Draft Copy
o
/0
o
=North 90
o
=East 180
o
=South 270
o
A89WS Weather Station (gen 3)
=West