Page 3
Installation should be done by a qualified installer only. Prior to Installation, the following must be For Vehicular Gate Operators utilizing a non- observed: (per UL 325 51.8.4) contact sensor in accordance with 30A.1.1 Type B1 non-contact sensor (photo electric Install the vehicular gate operator only when: sensor or the equivalent) 1) The Vehicular Gate Operator is appropri-...
“A” “C” UNC Red-head Anchor Bolts 18” concrete MODEL Dim "A" Dim "B" Dim "C" Dim "D" Dim "E" RAM-1000 UL 13-3/4" 8-1/2" 2-1/8" 14" 8-1/2" RAM-5500 UL 13.902 8.625 or 6.625 2.049 13.875 R A M S E T...
Figure 4 6” min. Dim “D” minus 24” Concrete Pad Rear Installation distance deter- mined by pulleys Gate Shown Fully Open No tail on gate required 18” x 18” 6” min. 2-1/2” diameter UHMW Pulley Center Installation Concrete Pad Gate Shown Fully Open No tail on gate required Figure 5 Low voltage control wires must be run in a separate conduit to the operator.
GATE TRAVEL ADJUSTMENT To adjust gate travel, depress spring loaded bracket and spin each Adjustment Nut to the required position (Figure 6). LED must turn on to indicate position open or close when limit switch is activated by limit switch adjustment nut. Figure 6 Limit Switches Adjustment...
Used with a three button switch or a pedestrian entranceto stop INTRODUCTION the gate. DIP FUNCTION Ramset’s “Intelligate” Control board is for operating a vehicular ‘off’ normal operation gate operator. The control board is available for either 110VAC ‘on’ normally closed contact. With an open contact the board or 220VAC, single phase, applications.
DIP SWITCH B5: “LAG DELAY” SAFETY INPUT DESCRIPTION Note: if both B5 & Lag on Close B6 are 'on', there One second lag on close Limit 1 & Limit 2 – Depending on dip switch B7 (see “dip will be NO lag on switch features”), stops the motor from moving in one direc- the open or close.
CAUTION Electronic Control Board must be serviced by a certified technician only. Power must be turned OFF before servicing operator. Power must be turned OFF before attempting to adjust the limit switches. Power must be turned OFF for power failure release. WIRING DIAGRAM Figure 10 NEUTRAL...
SENSOR INSTALLATION Reversing Sensors on the ground floor prevent WARNING gate from closing when vehicle is in loop area. A non-contact sensor (photoelectric sensor or Exit Loops on the ground floor opens gate equivalent) and a contact sensor (edge device or when vehicle crosses loop area.
BILL OF MATERIAL FOR RAM-1000 UL AND RAM-5500 UL ITEM PART # PART DESCRIPTION RAM-1000 UL RAM-5500 UL 50-031 1/2 hp 115 vac electric motor 50-039 20 pin edge connector 50-058 3 1/2" uhmw idler pulley 50-069 limit switch 00-h3...