RAMSET RESPONSIBILITIES OF INSTALLERS AND TECHNICIANS INSTALLATION: • READ AND UNDERSTAND THE INSTRUCTION MANUAL BEFORE ATTEMPTING ANY INSTALLATION. • DO NOT EXCEED THE EQUIPMENT SPECIFICATIONS. • INSURE A SAFE AND PROPER INSTALLATION. • INSTALL THIS EQUIPMENT IN ACCORDANCE WITH THE UL 325 SPECIFICATIONS.
__________________________________ _,,RA-"', \ "'I S ,_,E:.,.T IMPORTANT SAFETY REQUIREMENTS BY UL STANDARDS Prior to installation, the following must g) The stop and/or reset button must be located in be observed: (per UL325.56.8.4) the line-of-sight of the gate. Activation of the reset control shall not cause the operator to a) Install the gate operator only when: start.
RA.\tSET CLASSES OF VEHICULAR GATE OPERATORS Vehicular horizontal slide-gate operator (or system) - A vehicular gate operator (or system) that controls a gate which slides in a horizontal direction that is intended for use for vehicular entrance or exit to a drive, parking lot, or the like.
RA.\tSET INSTALLATION SPECIFICATIONS CONCRETE PAD CONSTRUCTION: Dimensions given for the pad are based on soil Gate Closed bearing shear of 2000 P.S.F. These figures may Outside Property have to be adjusted depending on local soil conditions. 1. Construct form for mounting pad according to See Fig, 5, 6, or 8 Inside Property for d.lstanoe of pad...
RAMSET HOOKUP ELECTRICAL POWER GATE TRAVEL ADJUSTMENT Fihl'iiil CAUTION: Clutch tension bolts need to be tightened to a minimum of 40 lbs. above weight of gate in order to avoid slipping. Outlet Leads lii·Miil Note: Eliminate outlet leads. Hookup your Gate travel is adjusted by loosening the limit Cams and electrical 15 amp wires direct to outlet.
RA.\tSET STANDARD INSTALLATION FOR GATES FROM 14' TO 18' IN LENGTH 5 0 " •■: • 34• 4 2 " 3 2 " 7 6 " 32 31 4' SHORT ARM DIM. OPERATOR PIVOT SHAFT CENTER LONG ARM DUA. SPACE A STANDARD GATE IN OPEN POSITION REQUIRED FOR...
RAMSET COMPACT INSTALLATION FOR GATES UP TO 14' IN LENGTH 2 7 " 24 1/4" 20" 44 1/4" ---- 2 4 " ..,...- OPERATOR ..PIVOT SHAFT CENTER _,;;;;;;;:;:;;.,,,..,..-"", o '"- N '!!"GAR"""M o"" M.,._ --, MINIMUM SPACE REQUIRED FOR COMPACT INSTALLATION 20"...
He.et RAMSET SENSOR INSTALLATION Ramset Gate Operators should not be in stalled without non-contact sensing devices such as Loop Detectors, photo electric sensors or the equivalent. & A non-contact sensor (photoelectric sensor or equivalent) and a contact sensor (edge WARNING;...
PUSHBUTTON CONTROLS Three pushbuttons are located under the dip switches lor operation of the gate (see Figure 11 ). The opening. stop and closing buttons can be utilized to set limit switches and verify proper system operation when installing or servicing an operator. l#l·ltlii■I Opening L.E.D.'s light up when Opening,...
RA.\tSET DIP SWITCH CONFIGURATION lii·PBIFI • lntelllgate" Control Board DIP SWITCH "A" Dip Switch "e· 3; "CONSTANT WARN" Dip Switch "A" 1, 2 & 3; AUTOMATIC TIMER TO CLOSE GATE (Constant warning when gate is in motion). 'O' Is "OFF" '1' Is "ON"...
Page 14
RAMSET DIP SWITCH "C" Dip Switch "C" 7; "LEFT/ RIGHT" Dip Switch "C" 1; "SECURE CLOSE" Function: Function: Left hand installations - Alt operators come factory Normal Operation set for lelt hand operation. When power is lost, then regained, control board Right hand installations - Reverses motor &...
Page 15
RA.\tSET TERMINAL STRIP CONNECTION FOR OPTIONAL ACCESSORIES hihl'iiill Reverse Loop Magnetic Lock • Electric Motor Fire Box Telephone - - - - - Edge Sensor 120 VAC 220 VAC Entry System · - -- - - - -- In order to use COMMON - - -- -- - -- - ·...
RAMSET TERMINAL STRIP CONNECTIONS accept any commands. After the 6 minutes the 24 VDC is removed from the alarm connection and the board resets to normal operation. Terminal # 1 - COMMON: Low voltage common. Terminal# 9 and 10 - LIMIT 1 & LIMIT 2: Direction depends on Dip Switch "C"...
RA.\tSET RAMSET "INTELLIGATE" CONTROL BOARD Introduction: sary board modifications between 11 O VAC and Ramset's "lntelligate" Control Board works 220 VAC single-phase applications. Some of the with Sliding, Swinging and Overhead vehicular functions of the Control Board are: 60 seconds gale operators.
Reverse, Exit Phantom JP4, JP5 & JP8 - & Sensor: Used with the Ramset ILD-24 plug-in loop detector. The Loop wires should be connected into the "LOOP INPUTS" plug. www.RamsetStore.com | (800) 878-7829 | Sales@RamsetStore.com...
Bill of materials item Part # Part DesCriPtioN ram 300 800-00-04 Chassis [R300] 800-02-04 Gear Reducer - Size 50, Ratio 80:1 [R300] 800-04-10 Motor, Standard - 120VAC 1/2 HP [R5000,R300,R302,R3000s,R2000s] 800-08-00 Pulley, Cast Iron - 5/8" x 10" (MA100) [R300] 800-08-45 Pulley, Cast Iron - 5/8"...
Page 21
Bill of materials item Part # Part DesCriPtioN ram 300 800-75-00 arm assemBly 800-28-00 Arm, Metal Tubing - 1" x 2" x 32" - 12 awg 800-28-01 Arm, Metal Tubing - 1" x 2" x 42" - 12 awg 800-28-30 Plastic End Cap - 1"...
RA.\tSET GATE ENTRANCE SAFETY PRECAUTIONS & WARNING: 1. Never let children operate or play with gate controls. Keep the controls away from children. 2. The entrance is for vehicles only. Pedestrians should use a separate entrance. 3. Always keep people, children and objects away from the gate while the gate is in operation. No one should cross the area of a moving gate.
Opening the way ... Important information for the homeowner Ask your technician about all the features of our new Ramset operator. Safety devices, such as reverse loops, phantom loops, photo eyes, or miller edges must be installed on your gate before the operator may be used. Ask your technician which safety devices best suit your safety needs.