6. CONTROL WATER VALVE

1) Disconnect the power source.
2) Close the water supply tap.
3) Disconnect the inlet hose from the water valve.
4) Clean the filter packing using a brush.
5) Replace the filter packing and inlet hose in their correct positions.
6) Open the water supply tap.
7) Connect the power source.
8) Check for leaks.
Control Water Valve
Inlet Hose
Filter Packing
14