Installation Practice - Scotsman MC 15 Service Manual

Electronic modular cubers r 404 a version
Table of Contents

Advertisement

Page 12
4.
Have all the electrical and plumbing
connections been made, and is the water supply
shut-off valve open?
5.
Has the voltage been tested and checked
against the data plate rating?
6.
Has the water supply pressure been
checked to ensure a water pressure of at least 1
bar (14 psi).
7.
Have the bolts holding the compressor down
been checked to ensure that the compressor is
snugly fitted onto the mounting pads?
8.
Check all refrigerant lines and conduit lines
to guard against vibrations and possible failure.
WARNING. This icemaker is not designed for outdoor installation and will not function in
ambient temperatures below 10°C (50°F) or above 40°C (100°F).
This icemaker will malfunction with water temperatures below 5°C (40°F) or above 35°C
(90°F).
9.
clean?
10. Has the owner/user been given the User
Manual and been instructed on the importance
of periodic maintenance checks?
11. Has the Manufacturer's registration card
been filled in properly? Check for correct model
and serial number against the serial plate and
mail the registration card to the factory.
12. Has the owner been given the name and
the phone number of the authorized SCOTSMAN
Service Agency serving him?
G. INSTALLATION PRACTICE
8/10. Vented drain line
Have the bin liner and cabinet been wiped
1. Hand shut-off valve
2. Water filter
3. Water supply line (flexible hose)
4. 3/4" gas male fitting
5. Power line
6. Main switch
7/9. Drain fitting
11. Open trapped vented drain
Page 12