Installation Practice - Scotsman EC 106 Service Manual

Electronic cubers with storage
Hide thumbs Also See for EC 106:
Table of Contents

Advertisement

Page 17
7.
Check all refrigerant lines and conduit
lines to guard against vibrations and possible
failure.
8.
Have the bolts holding the compressor down
been checked to ensure that the compressor is
snugly fitted onto the mounting pads?
9.
Have the bin liner and cabinet been wiped
clean?
10. Has the owner/user been given the User
9
8
1
3
2
WARNING. This icemaker is not designed for outdoor installation and will not function in
ambient temperatures below 10°C (50°F) or above 40°C (100°F).
This icemaker will malfunction with water temperatures below 5°C (40°F) or above 35°C
(90°F).
Manual and been instructed on the importance of
periodic maintenance checks?
11. Has the Manufacturer's registration card
been filled in properly? Check for correct model
and serial number against the serial plate and
mail the registration card to the factory.
12. Has the owner been given the name and
the phone number of the authorized SCOTSMAN
Service Agency serving him?
G.

INSTALLATION PRACTICE

4
5
7
6
1.
Hand shut-off valve
2.
Water filter
3.
Water supply line (flexible hose)
4.
3/4" male fitting
5.
Vented drain
6.
Open trapped vented drain
7.
Drain fitting
8.
Main switch
9.
Power line
Page 17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ec 126Ec 176Ec 206Ec 226

Table of Contents