B.
REPLACEMENT OF EVAPORATOR
TEMPERATURE SENSOR (BLUE PLUG)
1.
Remove front, left and top panels.
2.
Remove the evaporator cover and snap off
the two metal clip securing the sensor probe to
the serpentine.
3.
Trace the evaporator sensor terminal plug
on the rear side of the control box and remove it
from its socket by carefully pulling out theterminal
plug securing clip.
4.
To install the replacement evaporator sensor
follow the above steps in reverse.
C.
REPLACEMENT OF CONDENSER
TEMPERATURE SENSOR (BLACK PLUG)
1.
Remove front and left side panels.
2.
Trace the condenser sensor probe located
within the condenser fins on air cooled version
and withtrow it.
On water cooled version remove it by opening
the plastic strap (reusable) securing the probe to
the refrigerant liquid line.
3.
Trace the condenser sensor terminal plug
on the rear side of the control box and remove it
from its socket by carefully pulling out the terminal
plug securing clip.
4.
To install the replacement condenser sensor
follow the above steps in reverse.
D.
REPLACEMENT OF ICE LEVEL LIGHT
CONTROL (FOUR PINS BLACK PLUG)
1.
Remove the front, left and right side panels.
2.
Trace the ice level light control terminal plug
(the only one with four terminal pins) on the rear
side of the control box and remove it from its
socket by carefully pulling out the terminal plug
securing clip.
3.
Open the Storage Bin door and remove the
ice level light control assy secured to the metal
bracket by unloosing its two securing screws.
4.
Remove the PVC plastic plug from unit
base then with traw the entire ice level light
control cable and terminal plug through the hole
in the unit base.
5.
To instali the replacement ice level light
control follow the above steps in reverse.
NOTE. Slip in the ice level control cable in the
center of the plastic plug so to avoid any sort
of contact with the unit frame.
E.
REPLACEMENT OF P.C. BOARD
1.
Remove front and left side panel.
2.
Remove all sensor terminal plugs, located
on the rear side of P.C. Board, by carefully
releasing them out from their sockets clips.
3.
Disconnect the terminal board connection
plug from the rear side of P.C. BOARD then
unloose the four screws holding the same to the
plastic control box and remove it.
4.
To install the replacement P.C. BOARD
follow the above steps on reverse.
F.
REPLACEMENT OF THE WATER PUMP
1.
Remove front and right side panels.
2.
Locate the water pump in the front right
corner of the evaporator chamber.
3.
Unloose the screw and the yellow green
ground wire. Trace the pump electrical wire leads
and disconnect them.
4.
Remove the two screws securing the pump
to sump tank.
5.
Remove the plastic ice chute and through
the ice discharge opening trace the plastic hose
and disconnect it from the port of the pump body.
6.
Pull out the pump assy from sump.
7.
To install the replacement pump follow the
above steps in reverse.
G.
REPLACEMENT OF WATER INLET
SOLENOID VALVE
1.
Close the shut-off valve on the water supply
line and disconnect it from the water inlet fitting at
the rear of the modular cuber.
2.
Remove the right side panel and disconnect
the electrical leads from the solenoid valve.
3.
Unscrew the two screws securing the inlet
solenoid valve to the cabinet.
4.
Remove the corbin clamps and plastic hose;
the valve is now free.
5.
To install the replacement water inlet
solenoid valve follow the above steps in reverse.
H.
REPLACEMENT OF THE HOT GAS
VALVE COIL
1.
Remove the left side panel.
2.
Remove the hardware securing the hot gas
valve coil to its body.