Final Check List; Installation Practice - Scotsman MXG 327 Service Manual

Electronic modular cubers
Table of Contents

Advertisement

Page 11
Water drain
The recommended drain tube is a plastic or
flexible tube with 18 mm (3/4") I.D. which runs to
an open trapped and vented drain. When the
drain is a long run, allow 3 cm pitch per meter
(1/4" pitch per foot).
A vent at the unit drain connection is also required
for proper sump drainage.
Water drain - Water cooled models
Connect the 3/4" GAS male fitting of the condenser
water drain, using a second flexible tubing or a 3/
8" O.D. copper tubing, to the open trapped and
vented drain.
NOTE. The water supply and the water drain
must be installed to conform with the local
code. In some case a licensed plumber and/
or a plumbing permit is required.
F.

FINAL CHECK LIST

1.
Is the unit in a room where ambient
temperatures are within a minimum of 10°C
(50°F) even in winter months?
WARNING. This icemaker is not designed for outdoor installation and will not function in
ambient temperatures below 10°C (50°F) or above 40°C (100°F).
This icemaker will malfunction with water temperatures below 5°C (40°F) or above 35°C (90°F).
2.
around the unit for proper air circulation?
3.
4.
connections been made, and is the water supply
shut-off valve open?
5.
against the data plate rating?
6.
checked to ensure a water pressure of at least 1
bar (14 psi).
7.
been checked to ensure that the compressor is
snugly fitted onto the mounting pads?
8.
to guard against vibrations and possible failure.
9.
clean?
10. Has the owner/user been given the User
Manual and been instructed on the importance of
periodic maintenance checks?
11. Has the Manufacturer's registration card
been filled in properly? Check for correct model
and serial number against the serial plate and
mail the registration card to the factory.
G. INSTALLATION PRACTICE
8/10. Vented drain line
Is there at least a 15 cm (6") clearance
Is the unit level? (IMPORTANT)
Have all the electrical and plumbing
Has the voltage been tested and checked
Has the water supply pressure been
Have the bolts holding the compressor down
Check all refrigerant lines and conduit lines
Have the bin liner and cabinet been wiped
1. Hand shut-off valve
2. Water filter
3. Water supply line (flexible hose)
4. 3/4" gas male fitting
5. Power line
6. Main switch
7/9. Drain fitting
11. Open trapped vented drain
Page 11