5.2

Troubleshooting for the Image

1) Abnormality of image density / Gray balance
Defective area
Density/Gray balance
Printer section
Scanner
Printed image
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Image density
Fig. 5-1
Step
Check items
1
Check the density/gray balance.
2
Check test print image (07-113).
3
Are the original glass and CIS unit
dirty?
4
Is the image faded?
5
Is background fogging occurring?
6
Is there a blotch on the image?
7
Is the image transferred normally?
5 - 21
Gray balance
Prescription
Adjust the density.
Go to step 4 if there is any problem
on image.
Clean them.
Perform troubleshooting for faded
image.
Perform troubleshooting for back-
ground fogging.
Perform troubleshooting for blotched
image.
Perform troubleshooting for abnor-
mal transfer.
e-STUDIO163/166/203/206
TROUBLESHOOTING