3. Removing the Blank Exposure Lamp
1) Remove the blank exposure lamp. (See "Re-
moving the Blank Exposure Assembly.")
2) Remove the four screws
connector
.
1
Figure 4-405
3) Disconnect the connector
3
Figure 4-406
4) Remove the three screws
blank exposure lamp
5
Figure 4-407
COPYRIGHT © 1998 CANON INC.
Download service manual and resetter printer at http://printer1.blogspot.com
, and disconnect the
1
2
.
, and remove the
.
4
CANON NP6621 REV.0 FEB. 1998 PRINTED IN JAPAN (IMPRIME AU JAPON)
4. Removing the Blank Shutter Sole-
noid
1) Remove the blank exposure assembly.
2) Remove the blank top plate, and disconnect the
connector
. (See "Removing the Blank Expo-
sure Assembly.")
3) Remove the E-ring
from the blank shutter.
4) Remove the two screws
blank shutter solenoid.
1
Figure 4-408
5. Positioning the Blank Shutter Sole-
noid
Adjust the position of the solenoid so that bottom
A is 9.5 ±0.5 mm on both sides when the solenoid
is moved in the direction of ON. Do not force the
shutter excessively.
After the adjustment, check to make sure that
the solenoid moves smoothly.