MECHANICAL SYSTEM
8. Points to Note
When installing the feeding roller
that the belt pulley
attached to the feeding roller
is toward the rear of the copier.
2
1
Figure 4-367
9. Removing the Separation Roller
1) Open the right door, and remove the two mount-
ing screws
from the separation roller assem-
bly support plate
; then, remove the separa-
tion roller together with the pressure arm.
Figure 4-368
4–32
Download service manual and resetter printer at http://printer1.blogspot.com
, make sure
Front of copier
1
2
COPYRIGHT © 1998 CANON INC.
2) Remove the stop ring
separation roller
4
Figure 4-369
10.Points to Note
When installing the separation roller
sure that the D-cut in the roller collar is toward the
front of the copier.
Rear
1
Figure 4-370
CANON NP6621 REV.0 FEB. 1998 PRINTED IN JAPAN (IMPRIME AU JAPON)
, and remove the
.
3
, make
Front of copier