- Main pcb diagrams............12 - Components disassembly pictures........16 - Components specifications..........24 - Explode drawings..........26,30,34,38 - Parts list............28,32,36,40 - Parts list of colour components........42 - Pcb control functions............44 TYPES OF THE APROVED SAFETY STANDARDS Daewoo Electronics...
1m3 in size for every 8g of refrigerant R600a inside the appliance is shown on the identification plate inside the appliance. * Never start up an appliance showing any signs damage. If in doubt, consult your dealer. Daewoo Electronics...
PCB MAIN AS: 30143B9060 - Wiring diagrams and pcb circuits have been changed but rest of components and specifications that don´t appear in this manual are similar to the previous models, so for another spare refer to ERF-..4A Service manual: Daewoo Electronics...
3-EXTERNAL DRAWING 3.2- ALL MODELS 4- C/P DIFFERENCE BETWEEN ERF-...A AND ERF-...A..EU ERF-...A REFRIGERATOR HIGH SUPER FREEZER ERF-...A...EU FREEZER REFRIGERATOR SUPER Daewoo Electronics...
FREEZER COMPART- Do not put in any bottles MENT: containing liquids such as Cold air flow out from the beer or beverages becau- upper front duct and pas- se they may freeze and ses into the lower duct break Daewoo Electronics...
CORD POWER AS PIPE CONN B COVER ME HOUSING PIPE CHARGE CAP DRAINER DRYER AS SPECIAL WASHER R/C ABSORBER PIPE B(GUM) SPECIAL NUT R/C ABSORBER PIPE C CASE VAPORI BOX RELAY AS MUFFLER AS CHASSIS T-BOARD AS MUFFLER B AS Daewoo Electronics...
1.1- Take out control panel by pulling it up and inserting a minus driver like picture shows, and move it left-right. 1.2- Disconnect F-Pcb harness and switch lamp. 1.3- Remove 2 upper screws to take out base control panel. Daewoo Electronics...
Page 17
1.4- Dettach all connectors of M-Pcb and remove it. 1.5- Unscrew transformer. 2- COVER MULTI-DUCT. 2.1- Remove window lamp by pushing lower part and pulling forward. 2.2- Remove 3 fixing screws. Daewoo Electronics...
Page 18
2.3- Pull forward with snap force. 2.4- Remove lamp socket harness and R-Sensor harness by pressing the housings. 2.5- Remove insulator multi-duct. 2.6- Disassemble lamp socket unscrewing it. Daewoo Electronics...
Page 19
3- GASKET. 3.1- Take out the gasket as shown. 3.2- Fix the new one. 4- FREEZER COMPARTMENT. 4.1- Remove 3 fixing screws. 4.2- To prevent damage, remove louver using method as illustrated. Daewoo Electronics...
Page 20
4.3- Remove 2 fixing screws of louver FB. 4.4- Take out louver FB by hand, and disconnect fan motor housing. 4.5- Disconnect all housing conectors. 4.6- Unscrew evaporator and move it carefully to prevent excessive bending of gas pipes. Daewoo Electronics...
Page 21
- Join cut wires with the new fuse wires. - Cover joint point with insulated tape (best way is heat shrink tube). 4.8- To replace D-Sensor. - Take out D-Sensor from the lower part of evaporator cutting cable tie. Daewoo Electronics...
Page 22
(check D-Sensor wires assy in the picture) 4.9- Disassembly system of guide drainer heater cord: - Cut aluminium tape of guide drainer borders. Daewoo Electronics...
Page 23
- Disattach wires pulling them. 5-RELAY BOX. 5.1- Insert a screw driver like picture, and move it until locking section released. 6- VAPORY CASE. 6.1- Lift up drain case for disassemble guide lockers and pull it out. Daewoo Electronics...
Page 40
42 SHAFT HI 3014903200 43 HINGE *M 3012908001 DIE CASTING 44 HINGE *U 3012908201 P/O+ZN t3.2 45 COVER CAB BRACKET COLOUR PAGE HIPS 46 FOOT ADJUSTING AS 3012101800 PP+SPECIAL BOLT 47 CAP DRAIN HOSE 3010919700 48 CASE VAPORY 3011162600 Daewoo Electronics...
Page 41
95 ASSY R DOOR URT COLOUR PAGE ASSY 96 CAP DOOR BUSHING COLOUR PAGE 97 ASSY F DOOR URT COLOUR PAGE ASSY 98 GASKET F DOOR AS 3012306700 PVC+MAGNET 99 TEMPERATURE FUSE 3017200420 100 COMPRESSOR 3956190250 MK-490Q-L1U 101 D-SENSOR 3012733910 Daewoo Electronics...
3012627010 PBT + DARK GREY 17 COVER DOOR CAP *L 3011467310 18 COVER DOOR CAP *R 3011467410 19 CAP HANDLE 3010910010 HIPS 20 CAP SCREW 3010920210 HIPS 21 CAP DOOR BUSHING 3010918310 22 COVER CAB BRACKET 3011467510 HIPS Daewoo Electronics...
Page 43
3012626910 16 HANDLE *R 3012627010 17 COVER DOOR CAP *L 3011467310 18 COVER DOOR CAP *R 3011467410 19 CAP HANDLE 3010910010 HIPS 20 CAP SCREW 3010920210 HIPS 21 CAP DOOR BUSHING 3010918310 22 COVER CAB BRACKET 3011433310 HIPS Daewoo Electronics...
- RT ERROR : REF. RED LED is on & off two times. DISPLAY DISPLAY - LED - D1 ERROR D2 ERROR R1 ERROR RT ERROR - SHORT CIRCUIT CONDITION : LOW, MID, HIGH, VAC, SUPER LED lamps are all on Daewoo Electronics...
Page 45
•COMP & FAN will be on independent of the operation condition. kThe time limit of SHORT CIRCUIT OPERATION : 60 hrs Press TEMP. CONTROL button and make 1LED lamp on.(Case: DEFAULT MODE & ENERGY CONSUMPTION MODE) VACATION ON POINT : 8.0°C MODE 1 OFF POINT : 3.0°C Daewoo Electronics...
Page 46
Accumulated running time of Total running time of COMP RT-SENSOR COMP DEFROST Door Open Door Close Door Open Door Close RT 33°C- 24HR 24HR 18<RT< 32°C 12HR 30HR 48HR 75HR 15<RT< 17°C 24HR 24HR RT 14°C- 24HR 24HR Daewoo Electronics...
Page 47
• DISPLAY : REFRIGERATOR RED LED lamp in on & off two times. k CONTROL : The system is normally operating but the controlling by RT- SENSOR doesn’t work. l CANCELATION : when RT -SENSOR is working normally. Daewoo Electronics...
Page 48
TEMPERATURE - R-SENSOR Operating POINT increases 3- Condition of LOW RT TEMP B - R-SENSOR Operating POINT increases 1- 3) Check function of R-S HTR At initial operation,, R-SENSOR HTR turn on and off four times for 8sec. Daewoo Electronics...
Page 49
5) APPLICATION (MAIN PCB) • Default : MICOM8 PORT – 0V k Change of R OFF POINT 1.0 deg - : changing R42, R43 after deleting J2 •delete J2 kR42 : 10 l R43 : 10 KΩ KΩ Daewoo Electronics...
Page 50
• Temperature Adjustment : If you press the CONTROL button, it follows BUTTON 4 (MID, Default) → 5 → TURBO → VAC → 1 → 2 → 3 →4 ADJUSTMENT Ÿ If you don’t press the button again in 4 seconds, temperature will be set. Daewoo Electronics...
Page 51
• FORCED Defrost mode will be Started independent of the cycle. k The flow is same as the general defrost mode flow. 3) SHORT CIRCUIT OPERATION •COMP & FAN will be on independent of the operation condition. kThe time limit of SHORT CIRCUIT OPERATION : 60 hrs Daewoo Electronics...
Page 52
(This is to protect comp.) - FUNCTION of LOW RT PREVENTION 2) The COMP can’t be on within 6 min after comp. is off even though R-sensor is on OF COMP. condition. (This is to protect comp.) - DEFAULT OPERATIO N RESTART Daewoo Electronics...
Page 53
30 min : If you press FAST KEY continuously, you can reduce 30 minutes on TIME each second. REDUCTION 2) Practical Use : Can be applied to reduce needless time on test. EX) function of stop for 6 min Daewoo Electronics...
Page 54
Mode of General TEMP. or RT -SENSOR ERROR(open or short), R- LOW ROOM SENSOR HTR is off. TEMPERATURE Condition of LOW RT TEMP A - R-SENSOR Operating POINT increases 3- Condition of LOW RT TEMP B - R-SENSOR Operating POINT increases 1- Daewoo Electronics...
Page 55
R26 : DEL 5) APPLICATION (MAIN PCB) • Default : MICOM26 PORT– 0V k Change of R OFF POINT 1.0 deg - : changing R28, R26 after deleting J2 •delete J2 kR31 : 10 l R32 : 10 KΩ KΩ Daewoo Electronics...