C l e a n i n g o r r e p l a c i n g t h e a i r f i l t e r s
1 Disconnect the fixture from power. On each side of the head, remove the 2 screws that hold the side cover
using a Torx-20 screwdriver. Slide the cover forward to remove. Lift the filter off of the cover.
2 Clean the filters with a vacuum or compressed air, or replace them. If they are saturated with smoke fluid,
etcetera, soak them in warm soapy water and blot dry.
3 Place the filters on the covers and replace the covers.

Software installation

Software updates are installed in the MAC 2000 Performance II using a Martin MP-2 Uploader or a LightJockey 4064
DMX interface card. The procedure is found in the MP-2 user manual and the Martin Software Uploader online help
file.
R e q u i r e m e n t s
The following are required in order to install software.
• The MAC 2000 Performance II update file, available for download from the User Support Area of the Martin web site
(http://www.martin.dk).
• The Martin Software Uploader program, version 4.0 or later, available for download from the User Support Area of the
Martin web site.
• A Martin MP-2 Uploader connected to a Windows 95/98/ME/2000/XP PC, or a LightJockey Controller (DJ or Club)
with 4064 DMX Interface card.
Preventing software updates
Software updates are enabled by default, but you can disable this by setting the Write jumper (see "Circuit board
connections" on page 53) to disable.
Boot sector jumper
If the normal upload procedure does not work, or if the software update notes call for a boot sector update, move the
boot sector jumper on the printed circuit board to the BOOT position before uploading software.
S
E T T I N G T H E B O O T S E C T O R J U M P E R
1 Disconnect the fixture from power.
2 Remove the top screws from the ends of the front side panel and tilt the
panel down to expose the main circuit board.
3 Using the appropriate diagram in "Circuit board connections" on page 53 or
the label inside the base, locate the BOOT jumper (PL16). Move the jumper
to the "BOOT" position.
4 Perform a boot mode upload. When the upload is complete, disconnect the
fixture from power and move the jumper back to the locked or normal
position.