Typical application examples
The application examples given below are for illustration purposes only.
When the SAMSUNG Air-to-Water Heat Pump system is used in series with another heat source
(e.g. gas boiler), ensure that the return water temperature not exceed 55°C.
The unit is only to be used in a closed water system. Application in an open water circuit can lead to
excessive corrosion of the water piping.
SAMSUNG can not be responsible put responsible for incorrect or unsafe situations in the water
system. Make sure that the boiler, radiators, convectors, solar collectors, UFHs, FCUs, additional
pumps, pipings, and controls in the water system are in accordance with relevant local laws and
regulations under the installer's responsibility.
SAMSUNG shall not be held liable for any damage resulting from not observing this rule.
SAMSUNG do not provide specific water system components such as Pressure relief valve, Air vent
valve, buffer tank and etc. Installers and end-users shall consider how to install the above designated
components in overall water system depending on the installation conditions. If the components are
not installed in appropriate location, the water system can not be operated as designed.
The below examples are for illustration purposes only.
Application 1: Space heating
Outdoor
Our Supply Range
Outdoor unit
Indoor
Mixing Tank
Hydro-unit
Zone Thermostat & 2way Valve
Room
Controller
45°C
Supply Header
Return Header
Radiators or Convectors
[Application #2]
Thermostatic &
Load
Balancing Valves
Pump #1
Load
40°C
Pump #2
Supply Header
Return Header
Under-Floor Heating Coils
[Application #1]
[Application #4]
Differential Pressure bypass Valve
[Application #3]
Room Thermosat &
Actuators
Bypass
valve