G310 LOG_ UM_ENG V2.3 TT /JSan GENANO 310 OPERATING INSTRUCTION Page 2 ABLE OF CONTENTS TABLE OF CONTENTS GENANO 310 PURIFICATION DEVICE FOR INDOOR CLIMATE IMPORTANT SAFETY INSTRUCTIONS CONTENTS TECHNICAL FEATURES INSTALLATION AND OPERATING INSTRUCTIONS PARTS AND INDICATIONS OF SYMBOLS...
The MFI™ system is equipped with a gas absorber for the removal of harmful gases and ozone. The continued use and maintenance of the 310 air purifier will ensure you a comfortable breathing environment. The GENANO 310 is self-cleaning and requires only regular filling of Genano wash- ing fluid + water and to regularly empty the dirty flush water basin.
Polluted air Washing: Automatically runs washing cycle once a sucked into week. Always fill with GENANO washing fluid and wa- the air cleaner ter when the yellow “FILL WATER” light comes on. Empty the flush water basin regularly.
GENANO L GENANO ®TECHNOLOGY G310 LOG_ UM_ENG V2.3 TT /JSan GENANO 310 OPERATING INSTRUCTION Page 5 INSTALLATION AND OPERATING INSTRUCTIONS PARTS AND INDICATIONS OF SYMBOLS A. BOTTOM BASIN (basin for flush water / clean water container) B. SIGNAL LIGHTS OPERATION...
CHILDREN OR PETS WASHING LIQUID Genonex is premixed so just pour into watering container and pour in container (g) Take 1,5 liters of distilled water and 1 dcl of Genano MFI-washing fluid and mix in the watering can provided POSITIONING...
WALL MOUNTING It is possible to mount the GENANO 310 unit on the wall using brackets provided by Genano. Simply fasten the mounts to a wall capable of supporting 70kg by placing both brackets on the wall vertical to each other and 800mm apart from the metal mount (picture 1).
The yellow “FILL WATER” light is on (See signal lights) The 310 will continue its normal air cleaning operation even if one automatic wash cycle is missed due to a lack of washing mixture. However, the device stops the air-cleaning opera- tion if washing liquid/water is still not added after week to the wash water container.
1. Empty the flush water basin and fill the wash water container before performing the power wash. 2. Press the power wash switch and hold it down until the 310 machine starts the wash cy- cle (about 5 seconds) The Power wash lasts about 5 seconds. Following the power wash the “AUTOMATIC WASH/DRYING”...
GAS ABSORPTION PLATE Besides particles, the Genano air cleaner can also remove gases. Using a gas absorption plate, different kinds gases can be removed from the indoor air e.g. traffic originated sulphur- and nitrogen oxides as well as ozone. The typical exchange period of the gas absorption plate is 12 months.
Limited Corporation products. All Rights Reserved. FULL 12 MONTHS WARRANTY Genano Ltd warrants each new MFI™ Air Cleaning Product, Model against defects in materials or workmanship for a period of one year from the date of purchase, and agrees to repair or replace any defective product without charge.
1. Supervision is necessary when operated near children or the disabled. 2. Use this air purifier device for its intended indoor use, only, as described in manual. Do not use attachments not recommended by Genano Ltd. 3. Never use in an area with heavy wood dust or explosive chemicals.
GENANO L GENANO ®TECHNOLOGY G310 LOG_ UM_ENG V2.3 TT /JSan GENANO 310 OPERATING INSTRUCTION Page 14 Troubleshooting guide Warning! Repairs and maintenance work must be carried out by qualified personnel only. SYMPTOM CORRECTIVE ACTIONS The power does not turn on.
Need help?
Do you have a question about the 310 and is the answer not in the manual?
Questions and answers