CONNECTOR
NO. OF LOCATION
CN9
65001WS-12
CN1
SMW250-03
CN4
LWD1140-06
CN8
SMW250-04
CN11
Table 18 – Water Heater Wiring 1
PIN
BOARD SILK
1
-
2
L
3
CP1
4
IT
5
L(HT)
6
GV
7
8
N
9-12
1
2
RS-485
3
1
2
3
FAN
4
5
6
1
2
MCU ISP
3
4
1
HWL
8
2
LWL
10
3
HD
11
4
TH
12
5
APS
13
6
EL
14
7
BL
15
8
HL
16
DESCRIPTION
UNUSED
Power Supply Line
UNUSED
Ignitor
Ceramic Heater (Freeze Protection)
Gas Valve
EARTH GROUND
Power Supply Neutral
AC Power COM Line
RS485 +
GND
RS485 -
Unused
GND
VDD
Fan power (start coil)
Fan power (end coil)
Fan speed feedback signal
GND
ISP / Reset Port
ISP TOOL0 Data Port
VCC
Unused
Unused
Unused
Connect to the Display Control
(Thermostat)
Air Pressure Switch
Unused
Burner Limit
High Limit
30
HT SELV
-
HT (120V~)
SELV (5V)
-
SELV (30V)
SELV (14V)
SELV (30V)
SELV (14V)
SELV (5V)
-
SELV (14V)
WHL-004 REV. 12.17.14