Lp (Liquid Propane) Gas Pipe Sizing; Gas Connection Requirements - Westinghouse WGRTNG199 Nstallation & Maintenance Manual

Residential tankless water heater
Hide thumbs Also See for WGRTNG199:
Table of Contents

Advertisement

Maximum Natural Gas Delivery Capacity – Length of Corrugated Stainless Steel Pipe in Feet
Pipe Size
10
½"
82
¾"
192
1"
383
1 ¼"
639
1 ½"
1260
2"
2930
Table 11 – Natural Gas Delivery Capacity – Corrugated Stainless Steel Pipe – Refer to ANSI Z223.1 – National Fuel Gas Code,
Latest Edition
Maximum Natural Gas Delivery Capacity – Length of Black Iron Pipe (Sch. 40 Metallic) in Feet
Pipe Size
10
½"
172
¾"
360
1"
678
1 ¼"
1390
1 ½"
2090
2"
4020
Table 12 – Natural Gas Delivery Capacity – Black Iron Pipe – Refer to ANSI Z223.1 – National Fuel Gas Code, Latest Edition

3. LP (Liquid Propane) Gas Pipe Sizing

The following is intended for use for piping between a Single or Second Stage (Low Pressure) Regulator and the water heater. The
following tables list maximum capacity of pipe in cubic feet of gas per hour for an inlet pressure of 11 inches water column and specific
pressure drop of 0.5 inches water column based on 1.5 specific gravity for liquid propane.
Maximum Liquid Propane Delivery Capacity – Length of Corrugated Stainless Steel Pipe in Feet
Pipe Size
10
½"
129
¾"
303
1"
605
1 ¼"
971
1 ½"
1990
2"
4640
Table 13 – Liquid Propane Delivery Capacity – Corrugated Stainless Steel Pipe – Refer to ANSI Z223.1 – National Fuel Gas
Code, Latest Edition
Maximum Liquid Propane Delivery Capacity – Length of Black Iron Pipe (Sch. 40 Metallic) in Feet
Pipe Size
10
½"
291
¾"
608
1"
1150
1 ¼"
2350
1 ½"
3520
2"
6790
Table 14 – Liquid Propane Delivery Capacity – Black Iron Pipe – Refer to ANSI Z223.1 – National Fuel Gas Code, Latest Edition
B. GAS CONNECTION REQUIREMENTS
1. The gas connection fitting on the water heater is ¾" female NPT. NOTE: The pipe size must not be less than ¾".
2. The supply line must be sized for the maximum output of the water heater being installed. If there are additional gas appliances from
the main supply line, measure the size of the supply line according to the COMBINED total maximum BTUH draw for the appliances as
if they were operating at the same time.
3. Measure the length of the gas supply line from the gas meter to the water heater. Water heater must be installed downstream of the
gas meter to ensure adequate gas supply. Use the tables in this manual or refer to the gas line manufacturer's sizing information to
determine the correct supply pipe size.
4. A manual gas shut-off valve should be installed in the gas supply line close to the water heater. See Figure 12 for detail.
Cubic Feet per Hour (0.60 Specific Gravity, 0.5 WC Pressure Drop)
20
30
58
47
137
112
269
218
188
456
374
325
888
723
625
2080
1700
1470
Cubic Feet per Hour (0.60 Specific Gravity, 0.5 WC Pressure Drop)
20
30
40
118
95
81
247
199
170
466
374
320
957
768
657
1430
1150
985
2760
2220
1900
Cubic Feet per Hour (0.60 Specific Gravity, 0.5 WC Pressure Drop)
20
30
91
74
216
177
153
425
344
297
661
528
449
1400
1140
988
3290
2680
2330
Cubic Feet per Hour (0.60 Specific Gravity, 0.5 WC Pressure Drop)
20
30
40
200
160
137
418
336
287
787
632
541
1620
1300
1110
2420
1940
1660
4660
3750
3210
40
50
60
41
37
37
97
87
80
168
153
292
267
559
509
1320
1200
50
60
72
65
151
137
284
257
583
528
873
791
1680
1520
40
50
60
64
58
53
137
126
265
241
397
359
884
805
2080
1900
50
60
122
110
255
231
480
434
985
892
1480
1340
2840
2570
80
100
150
29
26
20
69
62
48
132
118
91
232
208
171
440
393
320
1040
933
762
80
100
150
56
50
40
117
104
83
220
195
157
452
400
322
677
600
482
1300
1160
928
80
100
150
45
41
31
109
98
75
208
186
143
307
270
217
696
621
506
1650
1480
1210
80
100
150
101
94
84
212
197
175
400
372
330
821
763
677
1230
1140
1010
2370
2200
1950
WHL-004 REV. 12.17.14
22
200
18
44
82
148
277
661
200
34
71
134
275
412
794
200
28
69
129
183
438
1050
200
67
140
265
543
814
1570