Elite 400W Pure Sine Inverter by Wagan Tech
Front Panel
•
ON/OFF Switch — This switch controls AC output of the inverter.
•
Operating LED (Green) — When this green LED is lit, the inverter is operating
normally.
•
FAULT LED (Red) — This indicator turns RED as the inverter shuts down
because of: Excessive Temperature, Overload, Under Voltage or Over
voltage.
Immediately turn off all AC appliances if the FAULT LED is lit. Allow the
inverter to cool before continuing. Make sure that the ventilation vents are not
blocked.
If an inverter "shutdown" was preceded by a buzzing sound, there may
excessive load, in combination with a low voltage or cable problem.
4
Operating
LED
AC Outlet
ON/OFF Switch
www.wagan.com
Fault LED
Cooling Vents
USB Power Port