Code
Contents
6120
Abnormally high fuser
thermistor 3 (press roller)
temperature
The fuser temperature
exceeds 200 °C/392 °F for 1
s.
6130
Fuser thermistor 3 (press
roller) break error
Fuser thermistor 3 does not
reach 30° C/86 °F even
after60 s during warming up.
The detected temperature of
fuser thermistor3 does not
reach the specified tempera-
ture (ready indication temper-
ature) for 200 s in warming up
after reached to 30° C/86 °F.
6150
Abnormally low fuser
thermistor 3 (press roller)
temperature
The fuser temperature lower
than 30 °C/86 °F is detected
continuously for 1 s.
Causes
Deformed connec-
If the I/F connector pins of the fuser unit and
tor pin.
the main unit are deformed owing to foreign
matters, such as paper dusts, replace the
connectors or the units including the con-
nectors.
Defective IH PWB.
Replace the IH PWB and check for correct
operation (see page 1-5-36).
Defective fuser
Replace the fuser unit (see page 1-5-18).
thermistor.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-32).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Fuser thermistor 3 and fuser PWB (YC4)
Fuser unit and engine PWB (YC22)
Deformed connec-
If the I/F connector pins of the fuser unit and
tor pin.
the main unit are deformed owing to foreign
matters, such as paper dusts, replace the
connectors or the units including the con-
nectors.
Defective IH PWB.
Replace the IH PWB and check for correct
operation (see page 1-5-36).
Defective fuser
Replace the fuser unit (see page 1-5-18).
thermistor.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-32).
Deformed connec-
If the I/F connector pins of the fuser unit and
tor pin.
the main unit are deformed owing to foreign
matters, such as paper dusts, replace the
connectors or the units including the con-
nectors.
Defective fuser
Replace the fuser unit (see page 1-5-18).
thermistor.
Defective fuser
heater.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-32).