Operating the Appliance
3.2

Switching the Appliance On/Off

Switching on
B Switch on the appliance at the master switch (I).
The indicator lamp shows green and the display will show the
central heating flow temperature, when the appliance is oper-
ating in the central heating mode.
6 720 610 333-04.1O
If the display alternates between -II- and the cen-
i
tral heating flow temperature, the trap filling pro-
gramme is active.
The trap filling programme ensures that the condensation trap is
filled after the appliance has been installed or after the appliance
has been out of use for a long period. For that reason, the appli-
ance remains at minimum heating output for 15 minutes.
Switching off
B Switch off the appliance at the master switch (0).
The green indicator lamp goes out. The optional timer will con-
tinue running until the emergency supply is exhausted.