Water Treatment; Starting The Appliance; Switching The Appliance On/Off - Worcester Greenstar Highflow 440CDi ERP Installation, Commissioning And Servicing Instructions

Floor standing rsf gas fired condensing combination boiler
Hide thumbs Also See for Greenstar Highflow 440CDi ERP:
Table of Contents

Advertisement

5.3

Water treatment

NOTICE: Debris from the system can damage the boiler
and reduce efficiency. Failure to comply with the
guidelines for the use of water treatment with the
appliance will invalidate the appliance warranty.
NOTICE: SOFTENED WATER
▶ ARTIFICIALLY SOFTENED WATER MUST NOT BE
USED TO FILL THE CENTRAL HEATING SYSTEM.
ENSURE THAT THE SYSTEM HAS BEEN CLEANED AS ON PAGE 11 OF
THESE INSTRUCTIONS.
INHIBITOR (Central Heating):
▶ Check drain cocks are closed and all radiator valves are open before
adding a suitable inhibitor compatible with aluminium (or combined
inhibitor/anti-freeze if the system is exposed to freezing conditions)
to the heating system water in accordance with the manufacturers
instructions.
The pH value of the system water must be less than 8 or
the appliance warranty will be invalidated.
▶ Fill the system to between 1 and 1.5 bar via the supplied internal
WRAS approved filling loop figure 32 on page 26.
▶ Vent the boiler and all radiators; retighten vents when complete.
▶ Record the date when the inhibitor was added to the system on the
guarantee card.
NOTICE:
▶ The concentration of inhibitor in the system should
be checked every 12 months or sooner if system
content is lost.
▶ The addition of sealing agents to the system water is
not recommended as this can cause problems with
deposits left in the heat exchanger.
▶ In cases where all attempts to find a micro leak have
failed, Worcester, Bosch Group supports the use of
Fernox F4 leak sealer.
6720818077 (2016/04) -
Greenstar Highflow CDi
ErP
5.4

Starting the appliance

2
1
13
12
4
3
5
2
11
1
6
max
10
Fig. 33 Fascia guide
[1]
Master switch for ON/OFF
[2]
Position for optional programmer
[3]
Display
[4]
System pressure gauge
[5]
Fault reset button (red)
[6]
ECO button (domestic hot water pre-heat ON/OFF) (green)
[7]
Not used
[8]
Domestic hot water temperature control
[9]
230V mains ON/OFF indicator + blue fault diagnostic light
[10] Central heating temperature control
[11] Service engineer button (orange)
[12] Service menu button (orange)
[13] Burner on indicator light (green)
5.4.1

Switching the appliance on/off:

NOTICE: Never run the appliance when the appliance or
system is empty or unpressurised.
▶ Turn on mains power supply.
Fig. 34 3 Amp fused double pole isolator
▶ Turn on any external controls.
▶ Set the TRV controls to maximum.
▶ Set the clock/programmer to continuously ON and the room
thermostat to maximum temperature.
▶ Press button [1] and the power on indicator [9] illuminates blue.
1
3
4
5
2
1
6
max
Fig. 35 Turning on the appliance
COMMISSIONING
2
1
1
3
0
4
bar
reset
eco
4
3
e
2
1
6
min
max
9
6720818977-13.1Wo
1
2
1
1
3
0
bar
4
reset
eco
3
4
e
2
1
6
min
max
6720818977-14.1Wo
9
3
4
5
6
7
8
27