Baxi Combi 130 HE User Operating Instructions Manual page 5

Gas fired wall mounted condensing combination boiler
Table of Contents

Advertisement

Lower Door Panel
Burner ON Indicator
(Orange Light)
LCD Display
o
C
Reset
Fig. 3
Temperature
Control Buttons
On/Off Reset
Fig. 4
Flame Failure Indicator
(Red Light)
1
2
3
0
o
C
Reset
Control Panel
2.3
Central Heating: The boiler will automatically
achieve the optimum flow temperature for
maximum comfort and efficiency.
1. However, in the case of the elderly, infirm or
very young, a lower radiator surface temperature
may be desirable. If so, the central heating flow
temperature can be adjusted between 45° C ± 3°
C minimum and 82° C ± 5° C maximum.
2. To set the required temperature, press and
hold the Central Heating Control Button (
whilst adjusting the necessary Temperature
Control Button (Fig. 4).
Domestic Hot Water: The boiler will
automatically achieve the optimum flow
temperature for maximum comfort and efficiency.
1. The temperature of the domestic hot water can
be adjusted between 35° C ± 5° C minimum and
55° C ± 5° C maximum.
Pressure Gauge
2. To set the required temperature, press and
hold the Domestic Hot Water Control Button (
whilst adjusting the necessary Temperature
Control Button (Fig. 4).
3. At a DHW temperature set point of 45° C the
flow rate can be reduced down to as low as 3.5
litres/min without any degradation of the hot water
control. No DHW will be provided at less than 3.5
litres/min.
NOTE: Two status indicators can be seen
through the badge (Fig. 3).
The right hand symbol is the red "Flame
Failure" indicator.
Domestic Hot Water
Control Button
The left hand symbol is the orange "Burner
Central Heating
ON" indicator.
Control Button
Summer/Winter
Mode Button
2.4
1. The appliance only needs resetting if the red
flame failure light is on (Fig. 3) or if the display
shows(
2. If the red flame failure light is on, press the
On/Off/Reset button (
flame failure light goes off.
3. If the display shows (
seconds, switch the power off for 10 seconds.
4. If this occurs persistently consult a competent
service engineer.
2.0 Operating the Boiler
Temperature Control
Resetting the Appliance
) for more than 10 seconds.
)(Fig. 4) until the red
Reset
) for more than 10
)
)
5