PROBLEM
13. Unit uses an
excessive amount of
salt or chemical
14. Continuous flow to
drain.
15. Salt water to service A. Inadequate Brine/Rinse setting for
CAUSE
A. Incorrect programming
B. Excessive water in storage tank
A. Internal seal pack leak.
B. Seal pack or brine piston jammed
in position.
C. Power failure while unit was in
regeneration.
desired salt dosage.
B. Low water pressure lengthens brine
draw time.
C. Too much brine in the storage tank
SOLUTION
A. Refer to the 'Programming' section and
verify all settings.
B. Refer to problems 9 & 10.
A. Replace seal pack as outlined in the
'Parts Replacement Guide' section.
B. Replace the seal pack or brine piston
as outlined in the 'Parts Replacement
Guide' section.
C. Restore power to unit. Verify that unit is
connected to a constant power source.
A. Refer to the 'Programming' section and
verify all settings.
B. Increase line pressure to a minimum of
20 psi (140 kPa).
C. Refer to problems 9 & 10.
TROUBLESHOOTING GUIDE