seconds and then show the current status. Toggle between
"OFF" (Timeclock backup is off) and "ON" (Timeclock
backup
is on) with the "+" or "-" key.
Note: Changing this setting will not change any of the
programmed values and will load the default Timeclock
Backup value of 3 days. Programming step 7 will be activated
when this is set to On.
Note: This option will only be available when the flowmeter is
plugged into the control
5
English or Metric
Press the "STATUS" key. The display will blink "dIP5" for 3
seconds and then show the current status. Toggle between
"En" (English units) and "MET" (Metric units) with the "+" or
"-" key.
6.
12 or 24 Hour Clock
Press the "STATUS" key. The display will blink "dIP6" for 3
seconds and then show the current status. Toggle between
"12 Hr" (12 hour clock) and "24 Hr" (24 hour clock) with the "+"
or "-" key.
7.
3/4" or 1" Meter
Press the "STATUS" key. The display will blink "dIP7" for 3
seconds.
Do not change setting from "3-4"
Note: The 3/4" meter setting is to be used with the Medallist
Series softener. The 1" meter setting is for future models.
SETTING THE MICROPROCESSOR
The microprocessor senses when it is installed as a Soft-Minder
the board will automatically reset the microprocessor to the factory settings.
Step 1 – Programming Time of Day
Press the "STATUS" key.
The display will blink "tod" for 3 seconds and then change to time
of day with the "minutes" digits blinking.
Adjust the "minutes" digits with the "+" or "-" keys.
Press the "REGEN" key to blink the "hours" digits.
Adjust the "hours" digits with the "+" or "-" keys.
Press the "REGEN" key to cycle back to "minutes"
Note: The "hours" setting scrolls through 1-12 AM and 1-12 PM.
Make sure the proper AM or PM indicator is shown when setting
the time.
Step 2 – Programming Regeneration Time
Press the "Status" key after setting the time of day.
The display will blink "tor" for 3 seconds and then change to the
time setting with the "ones" digit blinking.
Adjust regeneration time as time of day above.
Note: This option will not show if the "dIP 2" option is set to im-
mediate.
12
CULLIGAN MEDALLIST SERIES
off
3-4
control. Adding or removing any connection to
®
12:00
PM
2:00
AM