Culligan MEDALLIST SERIES Service Manual page 10

Medallist series automatic water conditioner
Hide thumbs Also See for MEDALLIST SERIES:
Table of Contents

Advertisement

TABLE 4 - SALT DOSAGE
Capacity
Salt
Dosage
8" ft
3
4
18,300
5
20,000 20,000 20,000
6
22,000 22,500 23,500
7
23,200 24,400 26,500
8
24,100 25,700 29,000
9
25,100 27,000 31,300
10
26,100 28,300 33,300
11
26,800 29,400 35,000
12
27,500 30,500 36,500
13
X
14
X
15
X
16
X
17
X
18
X
19
X
20
X
3. Treated Water Volume Set Point
Calculate the treated water volume set point using the following information:
• Softening capacity — Grains (based upon salt dosage setting).
• Compensated hardness of water supply — Grains Per Gallon
• Estimated daily water usage — Gallons Per Day (refer to Table 5)
TABLE 5 - Daily Water Usage
Persons in Household
2
3
4
5
6
7
8
9
10
Example - Meter: Softener Model Medallist 2M
Capacity @ 9 lb. Salt Dosage: 25,100 Grains
Compensated Water Hardness: 19 Grains Per Gallon
Estimated Daily Water Usage: 300 Gallons Per Day
Treated Water Volume Set Point =
Softening Capacity
Divide by Compensated Hardness
Result is total number of gallons
of soft water per regeneration
Subtract daily Water Usage (needed
as a reserve to ensure continuous
soft water until regeneration occurs).
Round down to nearest ten for Treated
Water Volume Set Point
Set "CAPG" to 102
8
CULLIGAN MEDALLIST SERIES
160 lb. Brine Tank
" A" Dimension
Capacity
Secondary (Only)
30 ft
45 ft
in.
3
3
X
X
7-3/4
9-1/2
11-1/4
13
14-3/4
16-1/2
18-1/4
20
21-3/4
31,500 38,400
21-1/2
32,500 39,200
25-1/4
33,300 40,400
34,100 41,200
35,000 41,800
X
42,400
X
42,900
X
43,500
Gallons Per Day
Softener Capacity
Compensated Hardness
250 lb. Brine Tank
" A" Dimension
Secondary
(cm)
in.
(cm)
19.7
6-5/8
16.8
24.1
8
20.3
28.6
9-3/8
23.8
33
10-7/8 27.6
37.5
12-1/4 31.1 10-1/4
42
13-5/8 34.6 11-5/8 29.5 10-1/2 26.7
46.3
15
38.1
51
16-3/8 41.6 14-3/8 36.5 12-1/2 31.7 10-1/2 26.7
55.2
17-3/4 45.1 15-3/4
59.7
19-1/8 48.6 17-1/8 43.5 14-1/2 36.8 12-1/2 31.7
64.1
20-1/2 52.1 18-1/2
21-7/8 55.5 19-7/8 50.5 16-1/2
23-1/4
59
24-5/8 62.5 22-5/8 57.5 18-1/2
26
66
27-3/8 69.5 25-3/8 64.5 20-1/2 52.1 18-1/2
28-3/4
73
150
225
300
375
450
525
600
675
750
— Water Usage
25,100 Grains
÷ 19 Grains per Gallon
1,321 Gallons
— 300 Daily Water Usage (One Day Supply)
1,021 Gallons
1,020 Gallon Setting
375 lb. Brine Tank
" A" Dimension
Primary
Secondary
in.
(cm)
in.
(cm)
4-5/8
11.7
5-1/2
14.0
3-1/2
6
15.2
6-1/2
16.5
4-1/2
7-3/8
18.7
7-1/2
19
5-1/2
8-7/8
22.5
8-1/2
21.6
6-1/2
26
9-1/2
24.1
7-1/2
8-1/2
13
33
11-1/2 29.2
9-1/2
40
13-1/2 34.3 11-1/2 29.2
47
15-1/2 39.4 13-1/2 34.3
42
14-1/2 36.8
21-1/4
54
17-1/2 44.5 15-1/2 39.4
47
16-1/2
24
61
19-1/2 49.5 17-1/2 44.5
26-3/4
68
21-1/2 54.6 19-1/2 49.5
Primary
in.
(cm)
8.9
11.4
14
16.5
19
21.6
24.1
42
47

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Medallist 8"Medallist 30 3Medallist 45 3

Table of Contents