SERVICE

Service Bulletin 4812 711 40329

AUTHOR: Robert Zimmermann
Last Update: 07/29/10
VERSION: 1.1
TITLE: Inverted condenser motorfan wires on Side by Side appliance.
SUBJECT: In some case it can happen, that the wires of the condenser motorfan are inverted at the main board or water
valve side. This generate a error of ice water dispensing. Means, by pressing the ice water paddle, water will come out
through the ice maker and not to the dispenser tube.
REMEDIAL ACTION
The failure can be corrected, if you invert the position of two pins at the main board connector or the two fastons at the
water valve side. The pictures below show you the both wiring/connectors of the condenser motorfan and the correct
wire/connector position at the main board and water valve side.