Gas Control Valve & Burner Assembly Replacement Information; Draining; Temperature-Pressure Rdief Valve Operation - Kenmore 153.335863 Owner's Manual

Power vent gas water heater
Table of Contents

Advertisement

Service
and Adjustment
(cont'd)
L.R Gas Control Valve & Burner
Assembly Replacement
Information
Draining
Tile water heater should be drained
if being shut down during
freezing temperatures.
Also periodic
draining
and cleaning
of
sediment
from the tank may be necessary.
AWARNING
I PROPANE
(L.R) GAS CONTROL
VALVE AN
BURNER
ASSEMBLY REPLACEMENT
INFORMATION.
For Propane (L.R) Gas Models Only:
Your water heater is equipped with a Propane (L.R) gas con-
trol valve and a main burner assembly with left hand threads
for the following fittings and their connections.
The connection
between
the manifold and the gas
control valve (A to B) are left hand threads.
The connection
between
the main burner
orifice
and the manifold (C to D) are left hand threads.
For ordering
these replacement
parts, please refer to
the "Repair
Parts" section of this manual.
"lhrn the Fas control knob to the "OFF"
position.
CLOSE
nae cold water inlet valve to thc water heater.
OPEN a nearby hot water faucet and leave open to allow for
draining,
Connect
a hose to the drain valve and terminate
to an ade-
quate drain.
OPEN the Water heater drain valve to allow for tank draining.
NOTE:
If the water heater
is _oing
to be shut down and
drained for an extended
period,
the drain valve should
be
left open with hose connected
allowing
water to terminate
to an adequate
drain.
Close the drain valve.
Follow instructions
in the "Filling The Water Heater" section.
Follow the lighting
instructions
in the "Lighting"
section to
restart the water heater.
Temperature-Pressure
Relief
Valve Operation
The temperature-pressure
relief valve must be manually operated
at least once a year,
TEMPERATURE-PRESSURE
DISCHARGE PIPE
Failure to install and maintain
a new properly
listed tempera-
ture-pressure
relief valve will release the manufacturer
from any
claim which might result from excessive temperature
or pressure.
i
AWARNING
If the temperature-pressure
relief valve on the appliance
weeps or discharges periodically, this may be due to thermal
expansion,
Your water
heater
may have a check valve
installed in the water line or a water meter with a check
valve. Consult the Sears Service Center for further informa-
tion. Do not plug the temperature-pressure relief valve.
AWARNING
When checking the temperature-pressure relief valve opera-
tion, make sure that (I) no one is in front of or around the
outlet of the temperature-pressure relief valve discharge line,
and (2) that the water manually discharged will not cause any
property damage because the water may be extremely hot.
If after manually operating the valve, it fails to completely
reset and continues to release water, immediately close the I
cold water inlet to the water heater, follow the draining
instructions, and replace the temperature-pressure
relief
valve with a new one.
29