Service and Adjustment
(cont'd)
L.P.Gas Control Valve & Burner
Assembly Replacement
Information
Temperature-Pressure
Relief
Valve Operation
The temperature-pressure
relief valve must be manually operated
at least once a year.
_WARNING
PROPANE (L.R) GAS CONTROL VALVE AN BURNER
ASSEMBLYREPLACEMENTINFORMATION.
For Propane(LR) GasModelsOnly:.
Your water heater is equippedwith a Pmpane (I-R) gascon-
_ol valveand a main burner assembly with left handthreads
for the followingfitUngs and their connec_on_
RELIEF VALVE
The connection between the manifold and the gas
control valve (A to B) are left hand threads.
The connection between the main burner orifice
and the manifold (C to D) are left hand threads.
For ordering these replacement
parts, please refer to
the "Repair Parts" section of this manual.
DISCHARGE
PIPE
Failure to install
and maintain
a new properly
listed tempera-
ture-pressure
relief valve will release the manufacturer
from any
claim which might result from excessive temperature
or pressure.
AWARNING
If the temperature-pressure relief valve on the appliance
weepsor discharges periodically, t his may be due to thermal
expansion. Your water heater may have a check valve
installed in the water line or a water meter with a check
valve. Consultthe SearsService Center for further informa-
tion. Do not plugthe temperature-pressure relief valve.
Draining
The water heater should
be drained if being shut down during
freezing
temperatures.
Also periodic
draining
and cleaning
of
sediment from the tank may be necessary.
Turn the _as control knob to the "OFF" position.
CLOSE
me cold water inlet valve to the water heater.
OPEN
a nearby hot water faucet and leave open to allow for
draining.
Connect
a hose to the drain valve and terminate
to an ade-
quate drain.
OPEN
the water heater drain valve to allow for tank draining.
NOTE:
If the water heater is going to be shut down and
drained for an extended
period, the drain valve should
be
left open with hose connected
allowing water to terminate
to an adequate drain.
Close the drain valve.
Follow instructions
in the "Filling The Water Heater" section.
Follow the lighting instructions
in the "Lighting"
section to
restart the water heater.
AWARNING
When checl_ng the temperature-pressure relief valveopera-
t]on, make sure that (I) no one is in front of or aroundthe
outlet of the temperature-pressure reliefvaivedischarge line,
and (2) that the water manuallydischarged will not causeany
property damagebecause the water may be extremely hot.
If after manually operating the valve, it fails to completely
reset and continuesto release water, immediately closethe
cold water inlet to the water heater, follow the draining
instructions, and replace the temperature-pressure relief
valve with a new one.