Electrical Connections
Accessories (continued)

Heating circuit pump 115 V

WARNING
In the case of underfloor heating
systems, a high limit aquastat
(immersion or strap-on type)
must be installed in the heating
supply downstream from the mixing
valve and the heating circuit pump.
In this case connect the heating
circuit pump to the high limit
aquastat (see separate Installation
Instructions).
Fig. 15
Connecting the 115 V pump
16
1. Install the heating circuit pump in
accordance with the manufacturer's
specifications and instructions.
Rated current: AC 4 (2) A
2. Disconnect the connector from the
heating circuit pump (if connected);
connect the 3-wire cable from the
heating circuit pump to connector
3. Insert connector
in the socket for
the heating circuit pump.
.