Specifications - Follett U300 Series Installation, Operation And Service Manual

U300 series/ud300 series beverage and ice dispenser
Hide thumbs Also See for U300 Series:
Table of Contents

Advertisement

Specifications

Electrical
Each icemaker and dispenser require a separate circuit with with electrical disconnect within 10 ft (6m).
Equipment ground required. Standard electrical – 115V, 60Hz, 1 phase. Maximum dispenser fuse – 20 amps,
Maximum icemaker fuse – 20 amps each.
Model
number
Single-sided models
U300
U300B
U300BR400A/W
U300BR400A/W
U300R800A/W
U300BR800A/W
Dual-sided models
UD300
UD300R400A/W
UD300R800A/W
Plumbing
Dispenser
Note:
Drains should be hard piped and insulated. Maintain at least 1/4" per foot (6mm per 304mm run)
slope on drain line run.
Water disconnect within 10 feet (3m) of dispenser is suggested for automatic load units.
Follett recommends use of a Follett model AFSYSTMFL4S water filter on icemakers connected
to automatic fill dispensers.
Icemaker
Icemaker
amperage
11.0 amps
11.0 amps
11.0 amps ea (2)
11.0 amps ea (2)
11.0 amps
11.0 amps
11.0 amps ea (2)
1" PVC slip joint for bin drain
1" PVC slip joint for beverage drain pan
1" PVC slip joint for beverage bath drain
Beverage connections
1/4" ID syrup beverage hose
3/8" ID carbonated water beverage hose
3/8" ID plain water beverage hose
(detailed specifications may be found in icemaker installation manual
packed with icemaker)
1/4" FPT water in
3/4" MPT drain
3/8" FPT condenser inlet (water-cooled condenser only)
1/2" FPT condenser drain (water-cooled condenser only)
Dispenser
amperage
6.0 amps
7.0 amps
6.0 amps
7.0 amps
6.0 amps
7.0 amps
8.0 amps
8.0 amps
8.0 amps