Electrical Installation; Electrical Wiring - MHSC CDVR33 Installation And Operating Instructions Manual

Cdv series direct vent gas fireplace
Table of Contents

Advertisement

CDV Series Gas Fireplace
REMOTE WAll MOuNTED SWITCh
A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall
switch in a junction box at the desired location on the wall. Figure 43. Do not extend beyond the wall switch wire
length provided.
NOTE: extended lengths of wire may cause the fireplace not to function properly. longer length of wire
is permitted if the wire is made out of larger gauge (diameter) wire. Always check with local code.
PILOT
HI
TH
TP
TH/TP
32
Do not connect wall
switch to (110V)
circuit.
ON
RS
OFF
Figure 43 - Wiring Diagram for Wall Switch

ElECTRICAl INSTAllATION

OPTIONAL REMOTE
WALL SWITCH
ON
OFF
OPTIONAL REMOTE
CONTROL
ON
OFF
69D0023