TROuBlEShOOTING
GENERAl TROuBlEShOOTING
SyMpTOM
pOSSIBlE CAuSE
1. Glass Soots
A. Flame impingement on logs
2. Flame burn
A. Insufficient oxygen being
blue and lifts
supplied
off burner
(ghosting)
69D0023
ACTION
A. Install log set per the instructions
Inspect the injector and air intake area. Make sure this area
does not have any blockage from debris and clean.
Check gas supply.
A. Ensure that the vent cap is installed properly and free of
debris. Ensure that the vent system joints are tight and have
no leaks. Ensure that no debris has been blocking the inner
air intake at the bottom back of the combustion chamber.
Ensure that the glass is properly secure and latched.
CDV Series Gas Fireplace
45