Cross Flow Fan And Indoor Fan Motor Removal Procedures - Panasonic CS-C18DKU Service Manual

Hide thumbs Also See for CS-C18DKU:
Table of Contents

Advertisement

12.2. Cross Flow Fan and Indoor Fan Motor Removal Procedures

1. In order to remove the Cross Flow Fan and Indoor Fan
Motor, Control Board need to be taken out by releasing all
the connectors as indicated below.
a. Release the CN-TH connector. (Fig. 5)
b. Release the CN-STM1 connector. (Fig. 5)
c. Release the CN-STM2 connector. (Fig. 5)
d. Release the CN-DISP connector. (Fig. 5)
e. Release the indicator. (Fig. 5)
f. Pull out the Drain Hose from outlet to remove the
Discharge Grille. (Fig. 5)
2. Release the 2 screws. (Fig. 6)
3. By pressing down the hook at the left, you will be able to
remove the Control Board. (Fig. 6)
4. Remove the screw at the Cross Flow Fan. (Fig. 7)
5. Remove the Bearing. (Fig. 8)
6. Remove the screws at the left of the Evaporator. (Fig. 8)
53
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU
Fig. 5
Fig. 6
Fig. 7
Fig. 8