11 3-way Valve

Works
Shipping
(Installation and
Re-installation)
Operation
Pumping down
(Transferring)
Evacuation
(Servicing)
Gas charging
(Servicing)
Pressure check
(Servicing)
Gas releasing
(Servicing)
3-way Valve (Liquid Side)
Shaft Position
Closed
(With valve cap)
Closed
(Clockwise)
(Connected manifold
gauge w/charging cylinder)
Open
(With valve cap)
Closed
(Clockwise)
Open
(Counter-clockwise)
(Connected manifold
Open
(Counter-clockwise)
(Connected manifold
Open
(Counter-clockwise)
Open
(Counter-clockwise)
(Connected manifold
Service Port
Shaft Position
Closed
Closed
(With cap)
(With valve cap)
Open
Closed
(Clockwise)
Closed
(With cap)
(With valve cap)
Closed
(With cap)
(Counter-Clockwise)
Open
(Counter-clockwise)
gauge)
Open
(Counter-clockwise)
gauge)
Closed
(With cap)
(Counter-clockwise)
Open
(Counter-clockwise)
gauge)
45
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU
3-way Valve (Gas Side)
Service Port
Close
(With cap)
Open
(Push-pin)
Open
Closed
(With cap)
Open
Open
(Connected manifold
gauge)
Open
Open
(Connected manifold
gauge)
Open
Open
(Connected manifold
gauge)
Open
Open
(Connected manifold
gauge)
Open
Open
(Connected manifold
gauge)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu-c18dkuCs-c24dkuCu-c24dku

Table of Contents