CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 8.5. Indoor Fan Speed Control 12.1. Indoor Electronic Controllers Removal Procedures 8.6. Outdoor Fan Speed Control 12.2. Cross Flow Fan and Indoor Fan Motor Removal 8.7. Vertical Airflow Direction Control Procedures 8.8. Horizontal Airflow Direction Control 12.3.
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 8 Operation Details 8.1. Cooling Operation • Cooling operation can be set using remote control. • This operation is applied to cool down the room temperature reaches the setting temperature set on the remote control.
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 8.2. Soft Dry Operation • Soft Dry operation can be set using remote control. • Soft Dry operation is applied to dehumidify and to perform a gentle cooling to the room. • This operation starts when the intake air temperature sensor reaches the setting temperature on the remote control.
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 8.3. Automatic Operation • Automatic operation can be set using remote control. • This operation starts to operate with indoor fan at SLo speed for 20 seconds to judge the intake air temperature. • After judged the temperature, the operation mode is determined by refering to the below standard.
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 8.4. Operation Control (For 8.4.1. to 8.4.6. information applies only to Cooling and Soft Dry Operation) 8.4.1. Restart Control (Time Delay Safety Control) • When the thermo-off temperature (temperature which compressor stops to operate) is reached during:- −...
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 8.4.5. Compressor Reverse Rotation Protection Control • If the compressor is operating continuously for 5 minutes or longer and the temperature difference between intake air and indoor heat exchanger is 4.5°F or less for continuous 2 minutes, compressor will stop and restart automatically.
Page 22
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 2. Norrowing Vertical Airflow Direction − During Anti-dew condensation prevention, Airflow Direction Auto-control angle change from 10° - 38° to 10° - 27° under Cooling and Soft Dry operation mode. − During Anti-dew condensation prevention, Airflow Direction Manual control angle change from 10°, 14°, 18°, 22°, 27° to 10°, 13°, 16°, 19°, 22°...
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 8.5. Indoor Fan Speed Control • Indoor Fan Speed can be set using remote control. 8.5.1. Fan Speed Rotation Chart COOL/ DRY CS-C24DKU CS-C18DKU S Hi 1620 1420 1570 1360 1450 1250 1360 1220 1260...
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU • Auto Fan Speed during Soft Dry operation: 1. Indoor fan will rotate alternately between off and Lo-. 2. At the beginning of each compressor start operation, indoor fan will increase fan speed gradually for deodorizing purpose.
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 8.7.2. Manual Control • When the vertical airflow direction is set to Manual using the remote control, the automatic airflow is released and the airflow direction louver move up and down in the range shown in the diagram.
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU - Stopped by OFF/ON operation button. - Timer OFF activates. - Quiet mode button is pressed. - Operation mode is changed. 8.10. Quiet Operation (For Cooling Operation or cooling region of Soft Dry Operation) • The Quiet operation is to provide quiet/cooling operation condition compare to normal operation.
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 8.11. Economy Mode Operation Purpose of this operation is to save or reduced electrical power consumption of the room air conditioner. However consumer is advised to use Economy Mode operation after the room temperature reaches the desired temperature.
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 8.14. Remote Control Signal Receiving Sound • Long beep sound will be heard when:- − Stopping the air conditioner using ON/OFF switch. − Stopping the Quiet Mode. − Stopping the Powerful Mode. • Short beep sound will be heard for others setting.
Page 36
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 1. This equipment must be earthed and installed with earth leakage current breaker. It may cause electrical shock if grounding is not perfect. 2. Do not install the unit at place where leakage of flammable gas may occur. If gas leaks and accumulates at arround of the unit, it may cause fire.
Page 37
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU Attached accessories Indoor/Outdoor Unit Installation Diagram Applicable piping kit CZ-4F5, 7AEN (CU-C18DK) CZ-52F5, 7, 10AN (CU-C24DK) SELECT THE BEST LOCATION INDOOR UNIT • There should not be any heat source or steam near the unit.
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 10.2. Indoor Unit 10.2.1. SELECT THE BEST LOCATION 10.2.3. TO DRILL A HOLE IN THE WALL (Refer to “Select the best location” AND INSTALL A SLEEVE OF section) PIPING 1. Insert the piping sleeve to the hole.
Page 40
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 10.2.5. INDOOR UNIT ELECTRICAL WIRING 1. Remove the control board metal cover. INSTALLATION OF AIR PURIFYING FILTER 1. Open the front panel. 2. Remove the air filters. 3. Put air purifying filter into place as shown in illustration at below.
Page 41
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU AUTO SWITCH OPERATION The below operations will be performed by pressing the “AUTO” switch. 1. AUTO OPERATION MODE The Auto operation will be activated immediately once the Auto Switch is pressed. 2. TEST RUN OPERATION (FOR PUMP DOWN/SERVICING...
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 10.3. Outdoor Unit 10.3.1. SELECT THE BEST LOCATION (Refer to “Select the best location” section) 10.3.2. INSTALL THE OUTDOOR UNIT MODEL Piping size (Torque) Liquid • After selecting the best location, start installation according C18DK 1/2”...
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 10.3.4. EVACUATION OF THE EQUIPMENT WHEN INSTALLING AN AIR CONDITIONER, BE SURE TO EVACUATE THE AIR INSIDE THE INDOOR UNIT AND PIPES in the following procedure. 1. Connect a charging hose with a push pin to the Low side of a charging set and the service port of the 3-way valve.
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 10.3.5. OUTDOOR UNIT ELECTRICAL WIRING 6. Secure the wire onto the control board with the holder (clamper). 7. Wire connection to the power supply (208/230V 60 Hz) through circuit breaker. • Connect the UL listed or CSA approved wires (AWG12) to the terminal board, and connect the other end of the wires to circuit breaker.
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 11 3-way Valve 3-way Valve (Liquid Side) 3-way Valve (Gas Side) Works Shaft Position Service Port Shaft Position Service Port Shipping Closed Closed Closed Close (With valve cap) (With cap) (With valve cap) (With cap)
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 11.1. Evacuation of Installation When installing an air conditioner, be sure to evacuate the air inside the indoor unit and pipes in the following procedure. Required tools : hexagonal wrench, adjustable wrench, torque If air remain in the indoor unit and refrigeration pipes, it will...
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 11.2. Pumping down Procedure: 1. Confirm that both the 3-way valves are set to the open 6. Operate the air conditioner at the cooling cycle and position. stop it when the gauge indicates 0 kg/cm G (0 PSI).
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 11.3. Evacuation of Re-installation WHEN REINSTALLING AN AIR CONDITIONER, BE SURE TO If air remain in the indoor unit and refrigeration pipes, it will EVACUATE THE AIR INSIDE THE INDOOR UNIT AND PIPES affect the compressor, reduce to cooling capacity, and could in the following procedure.
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 11.4. Balance refrigerant of the 3-way valves (Lack of refrigerant in the refrigeration cycle) Procedure: 1. Confirm that both the 3-way valves are set to the open position. 2. Connect the charge set to the 3-way valve’s service port.
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 11.5. Evacuation (No refrigerant in the refrigeration cycle) Procedure: 1. Connect the vacuum pump to the charge set’s centre hose. 2. Turn on the vacuum pump to evacuate the unit. • Confirm that the gauge needle has moved toward -76 cmHg (14.5 PSI)
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 11.6. Gas charging (After Evacuation) Procedure: 1. Connect the charge hose to the charging cylinder. 4. Immediately disconnect the charge hose from both the 3-way valve service ports. • Connect the charge hose which you disconnected from the vacuum pump to the valve at the bottom of the 5.
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 12 Servicing Information Caution: • Pb free solder has a higher melting point than standard solder; Typically the melting point is 50 - 70°F (30 - 40°C) higher. Please use a high temperature soldering iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C).
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 12.2. Cross Flow Fan and Indoor Fan Motor Removal Procedures 1. In order to remove the Cross Flow Fan and Indoor Fan Motor, Control Board need to be taken out by releasing all the connectors as indicated below.
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 7. Push up the Evaporator and pull out the Cross Flow Fan from shaft. By then, Fan Motor can be taken out. (Fig. 9) REMINDER - To reinstall the Fan Motor, put it back in place, adjust the position of the Fan Motor’s leadwire...
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 12.4. Auto OFF/ON Button • The “Auto OFF/ON Button” (behind the front grille) is used to operate the air conditioner if remote control is misplaced or malfunctioning. • Forced cooling operation is possible by pressing the “Auto OFF/ON Button” for more than 5s where “beep” sound is heard then release the button.
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 13 Troubleshooting Guide 13.1. Refrigeration cycle system In order to diagnose malfunctions, make sure that there are no electrical problems before inspecting the refrigeration cycle. Such problems include insufficient insulation, problem with the power source, malfunction of a compressor and a fan.
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 13.1.1. Relationship between the condition of the air conditioner and pressure and electric current Cooling Mode Condition of the air conditioner Low Pressure High Pressure Electric current during operation Insufficient refrigerant (gas leakage) Clogged capillary tube or...
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 15 Exploded View (Indoor Unit) 15.1. CS-C18DKU CS-C24DKU Note: The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts.
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 17 Exploded View (Outdoor Unit) 17.1. CU-C18DKU Note: The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts.
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 17.2. CU-C24DKU Note: The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts.
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU 18 Replacement Parts List (Outdoor Unit) <Model: CU-C18DKU> REF. NO. PART NAME & DESCRIPTION QTY. CU-C18DKU REMARKS BASE PAN ASSY CWD50K2056B SOUND PROOF BOARD CWH15223A FAN MOTOR BRACKET CWD54238 SCREW - FAN MOTOR BRACKET CWH55027...
Page 68
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU <Model: CU-C24DKU> REF. NO. PART NAME & DESCRIPTION QTY. CU-C24DKU REMARKS BASE PAN ASSY CWD50K2111A COMPRESSOR (60HZ, 208/230V) 2J39S236A1A ANTI - VIBRATION BUSHING CWH50055 NUT - COMPRESSOR MOUNT CWH4582065 PACKING CWB81043 CONDENSER CWB32C1577 SOUND PROOF BOARD...
Page 72
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU SCHEMATIC DIAGRAM 4/4 CAPACITOR BLUE C18DK BROWN OR YELLOW BLUE BROWN WHITE BLUE BLACK BLUE MAGNETIC RELAY YELLOW TEMPERATURE FUSE CAPACITOR BLUE C24DK THERMOSTAT BROWN OR YELLOW TO OUTDOOR ORANGE BLUE BROWN WHITE BLUE BLACK...
Page 73
CS-C18DKU CU-C18DKU / CS-C24DKU CU-C24DKU How to use electronic circuit diagram TIMER TABLE Test Mode Name Time (When test point Remarks Short-circuited) Real Timer 1 hr. 1 min. 10 min. 10 sec. 1 min. 1 sec. Time Delay Safety Control 2 min.