Appendix B Cabling Guidelines - Kingston Technology KNE16TP/RS User Manual

Etherx pro-series 19” rack-mount stackable 10base-t ethernet hubs
Table of Contents

Advertisement

16
Appendix B
Cabling Guidelines
Cable Types
When connecting network cables, the following table shows appropriate
networking guidelines associated with each cable type.
Ethernet Standard:
Cable Type:
Max. Segment
Length:
Max. Number of
Nodes per Segment:
Connector:
Network Topology:
Table B-1 Network Cable Guidelines
UTP Cable Wiring
10BASE-T unshielded twisted-pair cables can be wired as "Straight-Thru" or,
in some cases, "Crossover" depending on the application. For workstations
connected to a hub, use "Straight-Thru' wiring illustrated below in Table B-2.
In some instances (e.g. cascading from one hub to another), you may use
"Crossover" wiring illustrated below in Table B-3.
"Straight-Thru"
Cable Wiring
Pin Number
Pin Number
1 (TRX +)
1 (TRX +)
2 (TRX -)
2 (TRX -)
3 (RCV +)
3 (RCV +)
6 (RCV -)
6 (RCV -)
4, 5, 7, 8
Not Used
Table B-2. Straight-Thru Wiring
Kingston Technology Company
Appendix B
10BASE5
10BASE2
RG-11
RG-58/U
500M
185M
(1640ft)
(600ft)
100
30
15-pin D-Sub
BNC
Linear Bus
Linear Bus
Crossover"
Cable Wiring
Pin Number
1 (TRX +)
2 (TRX -)
3 (RCV +)
6 (RCV -)
4, 5, 7, 8
Table B-3. Crossover Wiring
KNE24TP/RS User's Guide - Rev. A01
Cabling Guidelines
10BASE-T
UTP CAT
3, 4 or 5
100M
(328ft)
1024
RJ-45
Star
Pin Number
3 (RCV +)
6 (RCV -)
1 (TRX +)
2 (TRX -)
Not Used