FLOOR PROTECTOR

 
Quadra-fire 2100 & 4300 Millennium ACC do not require a insulating Floor Protector, as they are tested
and comply with the minimum Floor Protector requirements of AS/NZS 2918:2001.
 
Note:
▪ The minimum Floor Protector sizes are specified in the clearance chart, see Table 1 & 2.
▪ A Floor Protector can include ceramic tiles with grouted joints fixed directly onto a wooden floor or a
sheet of toughened glass, panel steel or any other non combustible material laid directly onto a
wooden floor.
▪ If installed directly onto a concrete slab, the concrete slab can be considered as the floor protector,
but must maintain the minimum measurement listed.
 
 
 
 
PARALLEL POSITIONING
 
Fig. 3
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Table 1
 
 
Pioneer Double Flue Mounted Shield Universal
Pioneer Double Flue Mounted Shield Universal
 
A
Min. Clearance from firebox to rear wall
A
Min. clearance from firebox to rear wall
B
Min. clearance from firebox to side wall
B
Min. clearance from firebox to side wall
C
Min. distance from firebox opening to floor protector front
C
Min. distance from firebox opening to floor protector front
D
Min. distance from firebox to floor protector side
D
Min. distance from firebox to floor protector side
E
Min. distance from flue centre to side wall
E
Min. distance from flue centre to side wall
F
Min distance from rear wall to front of floor protector
F
Min. distance from rear wall to front of floor protector
G
Width of floor protector
G
Width of floor protector
 
 
NOTE: HEAT SHIELD REQUIREMENTS FOR HEAT SENSITIVE WALLS
Clearances may be reduced by provision of an appropriately located heat shield refer to
AS/ NZS 2198:2001 3.2.3 Table 3.1
Page 4
A
E
B
D
C
G
DESCRIPTION
DESCRIPTION
Shall be Fitted
Shall be Fitted
7037-141B
F
With Double Flue Shield Fitted
With Double Flue
Shield Fitted
2100-NZ
2100-AU
2100
4300
150
160
150
200
550
280
550
400
300
300
300
300
76
69
76
847
730
847
577
1034
1133
1034
1043
746
798
746
746
R
1.QF.1B
4300
200
400
300
76
69
730
1133
798
March 28, 2012