14
Alternate Sidewall venting for direct or non-direct venting:
1. Vent and/or air intake piping may be installed per figure
12a in order to provide enough clearance from snow line.
Maximum allowed equivalent vent and air intake length for
all of the approved vent and air intake materials is 30.48 m
(100 ft.) for B-120A and 15.24 m (50 ft.) for B-200A.
Figure12a: Sidewall venting and air intake piping
2. There is no restriction for the horizontal distance between
3. In cold climates, install an insolated enclosure around the
305 MM (12") MIN.
406 MM (16") MAX.
305 MM (12") MIN.
Bobcat Models B-120A and B-200A
air intake and flue terminals as long as they are on the
same side and the snorkel diagram is followed. Therefore,
there is NO minimum or maximum length given for this
horizontal pipe.
piping to protect from freezing.
508 MM (20") MAX.