Slant/Fin B-120A Installation And Operating Instructions Manual page 32

Direct-vent sealed combustion condensing boiler hot water gas-fired boilers for natural and l.p. propane gases
Hide thumbs Also See for B-120A:
Table of Contents

Advertisement

32
Press "SELECT" button for viewing different modes on "MODE DISPLAY"
MODE
DISPLAY
blinking
blinking
blinking
NOTE:
1-
For space heating mode "0" (boilers not utilizing outdoor sensor))
2-
For DHW mode "2" (storage tank with Aquastat)
3-
For DHW mode "1" (storage tank with sensor)
Table 4
VIEWING AND CHANGING TEMPERATURES
Temperature Display is in Farenheit only
DESCRIPTION & TEMPERATURE DISPLAY
Space heating supply water temperature could be changed by
pressing "Up/Down" button. Settable from 90°F to 185°F
(steps of 1 F). The default value is 176°F.
Domestic hot water supply temperature could be changed by press-
ing"Up/Down" button. Settable from 104°F to 185°F
(steps of 1 F). The default value is 176°F.
Domestic hot water tank temperature could be changed by
pressing "Up/Down" button. Settable from 104°F to 160°F
(steps of 1 F). The default value is 140°F.
Temperature display shows actual supply water temperature.
Temperature display shows actual return water temperature.
Temperature display shows actual DHW tank temperature.
(if the water tank is equipped with sensor).
Temperature display shows actual flue gas temperature.
Temperature display shows actual outside temperature.
Bobcat Models B-120A and B-200A
Press "Enter" button to store.
(see note 1)
Press "Enter" button to store.
(see note 2)
Press "Enter" button to store.
(see note 3)
(if outdoor sensor is used)