Slant/Fin B-120A Installation And Operating Instructions Manual page 12

Direct-vent sealed combustion condensing boiler hot water gas-fired boilers for natural and l.p. propane gases
Hide thumbs Also See for B-120A:
Table of Contents

Advertisement

12
Bobcat Models B-120A and B-200A
BOBCAT MODELS B-120A and B-200A NON - DIRECT VENT, UTILIZING AN EXISTING
CHIMNEY AS A CHASE
3"
3"
All joints must be liquid and pressure tight. Use
dia. Certified PVC or CPVC Venting or U/L listed single wall
dia.
AL29-4C S.S.*. venting materials (See page 7).
90° TERMINATION
ELBOW WITH SCREEN
*
ALTERNATE VERTICAL TERMINATION
45° ELBOW
* RAIN CAP TERMINATION MAY BE USED
VENT TERMINATION
TEE WITH SCREEN
3048mm
(10 FT.) MIN
305mm (1 FT.) MIN
3" DIA. CERTIFIED PVC OR CPVC
VENTING PIPE OR STAINLESS
STEEL VENTING MATERIAL FOR
VENT
SLOPE UP
20mm/m (1/4 IN
PER FOOT) MIN.
90° ELBOW
SEAL CHIMNEY OPENING
AIR INTAKE
WITH MORTAR OR COVER PLATE
(DO NOT BLOCK)
3" DIA. CERTIFIED PVC OR CPVC
VENTING PIPE OR STAINLESS
STEEL VENTING MATERIAL FOR
VENT
Figure 10. Bobcat models B-120A and B-200A - non-direct vent, utilizing an existing chimney as a chase.
* AL 29-4C IS A REGISTERED TRADEMARK OF ALLEGHENY LUDLUM CORP.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B-200aBobcat b-200a

Table of Contents