Minka-Aire Ultra F588-SP Instruction Manual

Minka-Aire Ultra F588-SP Instruction Manual

Hide thumbs Also See for Ultra F588-SP:

Advertisement

Quick Links

ULTRA
BY
INSTRUCTION MANUAL WARRANTY CERTIFICATE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ultra F588-SP and is the answer not in the manual?

Questions and answers

Summary of Contents for Minka-Aire Ultra F588-SP

  • Page 1 ULTRA INSTRUCTION MANUAL WARRANTY CERTIFICATE...
  • Page 2 Manual design and all elements of manual design are protected by U.S. Federal and/or State Law, including Patent, Trademark and/or Copyright laws.
  • Page 3 (excluding wall controls and electrical components), to the original purchaser or user. * The warranty is voided with the use of any non- Minka-Aire®electrical devices, E.g., wall controls or electrical dimmer switches, etc… * The warranty is void once the original purchaser or user ceases to own the fan or the fan is moved from its original point of installation.
  • Page 4 To obtain warranty service during the warranty period, the purchaser should return the fan with the sales receipt to the original place of purchase. The authorized Minka-Aire® dealer, at its sole discretion, will either repair or replace the fan after verifying the legitimacy of the warranty claim.
  • Page 5: Table Of Contents

    CONTENTS SAFETY RULES..................BLADE INSTALLATION................PACKAGE CONTENTS..............ATTACHING THE SWITCH CUP............INSTALLING THE FAN..............OPERATING THE REMOTE CONTROL/WALL CONTROL ..HANGING THE FAN................. CARE OF YOUR FAN................ELECTRICAL CONNECTIONS............TROUBLESHOOTING................INSTALLING THE WALL TRANSMITTER......... SPECIFICATIONS..................FINISHING THE INSTALLATION..........1151 W. Bradford Court, Corona, CA 92882 For Customer Assistance Call: 1-800-307-3267...
  • Page 6: Safety Rules

    SAFETY RULES 1. Before you begin installing the fan, shut power off at the circuit breaker of the fuse box. 2. Be cautious! Read all instructions and safety information before installing your new fan. Review accompanying assembly diagrams. 3. Make sure that all electrical connections comply with local codes, ordinances, or National Electrical Codes. Hire a qualified electrician or consult a do-it-yourself wiring handbook if you are unfamiliar with installing electrical wiring.
  • Page 7 NOTE: The important safeguards and instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur. It must be understood that common sense, caution and care are factors which can not be built into this product. These factors must be supplied by the person (s) installing, caring for and operating the unit.
  • Page 8: Package Contents

    PACKAGE CONTENTS Unpack your fan and check the contents. You should have the following items: 1. Fan blades (5) 13. Extra Wall Plate w/2 Mounting screws 14. Receiver (includes 6 wire nuts) 2. Hanger bracket 15. Balancing kit 3. Canopy 4.
  • Page 9: Installing The Fan

    To hang your fan where there is an existing fixture but no ceiling joist, you may need to install UPSIDE HANGER RECESSED BRACKET OUTLET BOX ® a hanger bar as shown in Fig. 4 (available at your Minka-Aire dealer). FIG. 3 FIG. 4...
  • Page 10: Hanging The Fan

    HANGING THE FAN WARNING: All of the parts, hardware and components such as the Step 4. Carefully feed fan wires up through the downrod. (Fig. 8) hanger bracket and hanger ball have been provided for your safety and Thread the rod into the coupling, next line up holes and replace lock the proper installation of your new ceiling fan.
  • Page 11 DOWNROD CANOPY OUTLET BOX COUPLING *OMIT COUPLING DOWNROD CROSS PIN COVER WHEN USING SET SCREWS THE MINIMUM-LENGTH HITCH CANOPY COVER DOWNROD LOCK HANGER SUPPLY REGISTRATION BALL SET SCREW WIRES SLOT SET SCREWS DOWNROD HANGER BRACKET Fig. 10 Fig. 5 Fig. 6 Fig.
  • Page 12: Electrical Connections

    ELECTRICAL CONNECTIONS WARNING: To avoid possible electrical shock be sure electricity is Step 2. Motor to Receiver Electrical Connections: Connect the WHITE turned off at the main fuse or breaker box before wiring. wire from the fan to the WHITE wire marked "TO MOTOR N" from the Receiver.
  • Page 13 Step 3. Receiver to House Supply Wires Electrical Connections: Connect the WHITE wire (Neutral) from the outlet box to the WHITE wire marked "AC in N" from the receiver. Connect the BLACK wire (Hot) from the outlet box to the BLACK wire marked "AC in L" from RECEIVER the receiver.
  • Page 14 INPUT AC120V OUTLET BOX *Wall Control Only WHITE (NEUTRAL) BLACK (HOT) WHITE GREEN OR BARE AC SUPPLY COPPER (GROUND) BLACK ("AC IN L") BLACK WHITE ("AC IN N") RECEIVER BLACK ("TO MOTOR L") WHITE ("TO MOTOR N") ORANGE GROUND (CONNECT TO GROUND- (FOR UPPER LIGHT) GROUND WIRE ON...
  • Page 15: Installing The Wall Transmitter

    INSTALLING THE WALL TRANSMITTER (Wall Control Only) WARNING! HOOK UP "IN SERIES" ONLY. DO NOT CONNECT NEUTRAL SUPPLY WIRE OF ELECTRIC CIRCUIT TO THE TRANSMITTER WALL SWITCH, DAMAGE TO THE TRANSMITTER WALL SWITCH AND POSSIBLE FIRE COULD OCCUR. Step 1. Remove the existing wall plate and switch from the wall outlet box. Step 2.
  • Page 16: Finishing The Installation

    FINISHING THE INSTALLATION OUTLET BOX Step 1. Remove 1 of the 2 screws from the bottom of the hanger bracket and loosen the other one half a turn from the screw head. HANGER BRACKET Step 2. Slide the canopy up towards the hanger bracket and place the key hole on the canopy over the screw on the hanger bracket, turn canopy until it locks in place at the narrow section of the key holes.
  • Page 17: Blade Installation

    BLADE INSTALLATION THE FOLLOWING OPERATION MUST BE ACCOMPLISHED BEFORE INSTALLING THE LIGHT KIT. SCREWS Caution: Remove 5 rubber packing mounts and discard before FIBER installation. WASHERS Step 1. Attach the fan blade to the blade holder using the BLADE screws and fiber washers provided. Tighten screws securely. Repeat process for remaining blades.(Fig.
  • Page 18: Attaching The Switch Cup

    ATTACHING THE SWITCH CUP Remove the screws from the switch cup plate. Slide switch cup up against plate and rotate it until the screw holes are aligned. Secure switch cup to plate using the screws removed earlier. (Fig. 18) NOTE: DO NOT PINCH WIRES BETWEEN THE SWITCH HOUSING AND THE SWITCH CUP PLATE. SWITCH CUP PLATE SCREWS...
  • Page 19: Operating The Remote Control/Wall Control

    OPERATING THE REMOTE CONTROL/WALL CONTROL Remote Control only: Install a A23 12 volt battery (included). To prevent damage to transmitter remove the battery if not used for long periods of time. Restore Power to Ceiling Fan. instructions apply to ceiling fans that feature a DOWN D.
  • Page 20 Speed settings for warm or cold weather depend on factors such as room size, ceiling height and number of fans. NOTE: To change the direction of the rotation of the blades the fan must be in operation mode. Warm Weather (forward) A DOWNWARD airflow creates a cooling effect as shown in Figure 19.
  • Page 21: Care Of Your Fan

    CARE OF YOUR FAN 4. Use a lint free lightly damp cloth or duster to remove dust from Here are some suggestions to help maintain your fan. the blades. 1. Because of the fan's natural movement some connections may become 5.
  • Page 22: Troubleshooting

    TROUBLESHOOTING SYMPTOM SYMPTOM SYMPTOM SYMPTOM Fan Wobble Fan will not start Fans/Light Turn On Fan Sounds Noisy SOLUTION and Off Unexpectedly SOLUTION SOLUTION Check to make sure the wall switch is turned NOTE: All blade sets are grouped by Allow a 24-hour "break in" SOLUTION weight.
  • Page 23 SYMPTOM Frequency Interference SOLUTION Turn the power off to your ceiling fan. Please use a small size tool to change the frequency settings on the control system. Return power to the unit. Note: After the AC power is on, do not press any other button on the transmitter before pressing the "Stop" button, doing so will cause the procedure to fail.
  • Page 24: Specifications

    SPECIFICATIONS These are typical readings. Your actual fan may vary. Fan Size Speed Volts Amps Watts N.W. G.W. C.F. They do not include amps and wattage used by the 0.31 12.2 2019 light(s). 10.7 11.8 54" Medium 0.47 33.7 4147 1.65' High 0.64...
  • Page 25 2019 12.2 4147 33.7 6341 76.4...

Table of Contents