8.
Remove the bottom plate (A) from the tray.
9.
Remove the two screws securing the bracket (B) to the tray.
10.
Remove the rear media guide (C).
11.
Remove the mylar actuator (D) by sliding it out of the tray in the direction of the arrow.
Note: Before re-installing, ensure the bosses on the rear media guide (C) are fitted into the slots on the mylar
actuator (D) as shown in the figure.
4024-XXX
4-67