Special Conditions Created
by Mechanical
Exhausting
or
Fireplaces: operation of exhaust fans, ventilation
systems,
clothes dryers or fireplaces may create conditions requiring
special attention to avoid unsatisfactory operation of installed
gas utilization
equipment.
Water Piping
Water
temperature
over
125°F
(52°C) car cause severe burns
instantly resulting in severe injury
or death.
Children,
elderly,
and
the
physically
or mentally
disabled
are at h ghest risk_or scald injury
Feel
water
before
bathing
or
showering.
Temperature
limitr_g valves are
available.
Read instruction manuaJ for safe
temperature setting
HOTTER WATER CAN SCALD:
Water heaters are intended to produce hot water. Water heated
to a temperature
which
will satisfy space
heating,
clothes
washing,
dish washing,
cleaning and other sanitizing
needs
can scald and permanently
injure you upon contact.
Some
people are more likely to be permanently
injured by hot water
than others.
These include the elderly, children, the infirm, or
physically/mentally
handicapped.
If anyone using hot water in
your home fits into one of these groups or if there is a local
code or state law requiring a certain temperature
water at the
hot water tap, then you must take special precautions.
In
addition to using the lowest possible temperature
setting that
satisfies your hot water needs, a means such as a *mixing
valve, shall be used at the hot water taps used by these people
or at the water heater. Mixing valves are available at plumbing
supply or hardware
stores, see Figure 14 below. Valves for
reducing point of use temperature
by mixing cold and hot water
are also available.
Follow
manufacturer's
instructions
for
installation of the valves.
Before changing
the factory setting
on the thermostat, read the Temperature Regulation
section in
this manual.
HOT WATER
OUTLET
*MIXiN
VALVE
COLD WATER
, INLET
,OCeLOWATE
INLET ON
FROM
WATER
HEATER
HOT WATER
OUTLET
ON
WATER HEATER
FIGURE14.
Toxic Chemical
Hazard
• Do not connect to non-potablewater system.
This water heater shall not be connected to any heating systems
or component(s)
used with a non-potable
water
heating
appliance.
All piping components
connected to this unit for space heating
applications
shall be suitable for use with potable water.
Toxic chemicals, such as those used for boiler treatment shall
not be introduced into this system.
Water supply systems may, because of such events as high
line pressure, frequent cut-offs or the effects of water hammer
among
others,
have installed
devices
such as pressure
reducing valves, check valves, back flow preventers,
etc. to
control these types of problems.
When these devices are not
equipped with an internal by-pass, and no other measures are
taken, the devices cause the water system to be closed.
As
water is heated, it expands (thermal
expansion)
and closed
systems do not allow for the expansion of heated water.
The water within the water heater tank expands as it is heated
and increases the pressure of the water system.
If the relieving
point of the water heater's temperature-pressure
relief valve is
reached,
the valve will relieve the excess
pressure.
The
temperature-pressure
relief valve is not intended
for the
constant relief of thermal expansion. This is an unacceptable
condition and must be corrected, It is recommended that any
devices installed which could create a closed system have a
by-pass and/or the system have an expansion tank to relieve
the pressure built by thermal expansion
in the water system.
Refer to the Thermal Expansion section under Troubleshooting
Guide or contact local plumbing authority or local Sears Service
Center on how to control this situation.
NOTE: To protect against untimely corrosion of hot and cold
water fittings, it is strongly recommended
that di-electric
unions or couplings be installed on this water heater when
connected to copper pipe.
Property
Damage
Hazard
• Avoid water heater damage.
• Install thermal expansion tank if necessary.
• Do not apply heat to cold water inlet.
• Contact qualified insta/ier or Sears Service Center
12
Figure 15 shows the typical attachment of the water piping to
the water heater. The water heater is equipped with 3/4" NPT
water connections.
NOTE: if using copper tubing, solder tubing to an adapter
before
attaching
the adapter
to the cold water
inlet
connection.
Do not solder the cold water supply line directly
to the cold water inlet. It will harm the dip tube and damage
the tank.
Look at the top cover of the water heater. The water outlet is
marked "HOT". Put two or three turns of teflon tape around
the threaded
end of the threaded-to-sweat
coupling and
around both ends of the 3/4" NPT threaded
nipple. Using
flexible connectors,
connect the hot water pipe to the hot
water outlet on the water heater.